STUDY ON THE INFLUENCE OF HYDRAULIC BULGING RESTRAINT INTENSITY ON MICROSAMPLE OF MAIN PIPELINE MATERIAL

Three kinds of micro-sample thicknesses(0.4 mm,0.5 mm and 0.6 mm)and three kinds of chamfer radii(0.5 mm,0.8 mm and 1.0 mm)of the original main pipe material were taken as the research objects to analyze the influence of restraint intensity in hydraulic bulging test,and to build a correlation model of yield strength,tensile strength and hydraulic bulging elongation.The fitting error of yield strength and tensile strength and the dispersion of hydraulic bulging elongation were studied.The results show that with the gradual increase of microspecimen thickness,the peak load increases obviously,while the peak displacement generally decreases,but the overall curve trend changes little.With the gradual decrease of the microsample chamfer radius,the peak displacement decreases obviously.The test stability is best under the test conditions of microsample thickness 0.5 mm and chamfer radius 1.0 mm.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
Primary Topic
Diverse Scientific Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

STUDY ON THE INFLUENCE OF HYDRAULIC BULGING RESTRAINT INTENSITY ON MICROSAMPLE OF MAIN PIPELINE MATERIAL

SHILAP Revista de lepidopterología
Diverse Scientific Research Studies
article

STUDY ON THE INFLUENCE OF HYDRAULIC BULGING RESTRAINT INTENSITY ON MICROSAMPLE OF MAIN PIPELINE MATERIAL

article en

Abstract

Three kinds of micro-sample thicknesses(0.4 mm,0.5 mm and 0.6 mm)and three kinds of chamfer radii(0.5 mm,0.8 mm and 1.0 mm)of the original main pipe material were taken as the research objects to analyze the influence of restraint intensity in hydraulic bulging test,and to build a correlation model of yield strength,tensile strength and hydraulic bulging elongation.The fitting error of yield strength and tensile strength and the dispersion of hydraulic bulging elongation were studied.The results show that with the gradual increase of microspecimen thickness,the peak load increases obviously,while the peak displacement generally decreases,but the overall curve trend changes little.With the gradual decrease of the microsample chamfer radius,the peak displacement decreases obviously.The test stability is best under the test conditions of microsample thickness 0.5 mm and chamfer radius 1.0 mm.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 32%
Diverse Scientific Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.