Preliminary Study on Fault Detection in Gas Coolers for Transcritical CO2 Refrigeration Systems

Carbon dioxide is acknowledged to be the refrigerant for next generation supermarket refrigeration systems. However, a notable dearth of research exists in fault detection and diagnosis applied to transcritical CO2 supermarket refrigeration systems. This paper addresses this knowledge gap by conducting a preliminary study on the impact of fouling in the gas cooler air side on the system performance over 7 hours of a typical summer day in Washington DC. The investigation was based on a dynamic model of a transcritical CO2 supermarket refrigeration system and 3 fouling scenarios, i.e., mild, moderate, and severe scenario. A grey-box model was developed to estimate the UA-value of the gas cooler. The findings demonstrated that this approach can be effectively utilized to detect fouling scenarios. Moreover, it was observed that the fouling results in increase in the electricity bill by 7.9 % and by 40.5 % in the moderate and severe scenario, respectively.

Institutions

Publication Details

Journal
University of Southern Denmark Research Portal (University of Southern Denmark)
Published
2024-08-14
Primary Topic
Diverse Scientific and Economic Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preliminary Study on Fault Detection in Gas Coolers for Transcritical CO2 Refrigeration Systems

University of Southern Denmark Research Portal (University of Southern Denmark)
Diverse Scientific and Economic Studies
article

Preliminary Study on Fault Detection in Gas Coolers for Transcritical CO2 Refrigeration Systems

article en

Abstract

Carbon dioxide is acknowledged to be the refrigerant for next generation supermarket refrigeration systems. However, a notable dearth of research exists in fault detection and diagnosis applied to transcritical CO2 supermarket refrigeration systems. This paper addresses this knowledge gap by conducting a preliminary study on the impact of fouling in the gas cooler air side on the system performance over 7 hours of a typical summer day in Washington DC. The investigation was based on a dynamic model of a transcritical CO2 supermarket refrigeration system and 3 fouling scenarios, i.e., mild, moderate, and severe scenario. A grey-box model was developed to estimate the UA-value of the gas cooler. The findings demonstrated that this approach can be effectively utilized to detect fouling scenarios. Moreover, it was observed that the fouling results in increase in the electricity bill by 7.9 % and by 40.5 % in the moderate and severe scenario, respectively.

University of Southern Denmark Research Portal (University of Southern Denmark)
Danfoss (China) (CN), IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbH (IMMS GmbH) (DE), Linz Center of Mechatronics (Austria) (AT), Aalborg University (DK)
Openalex Percentile: Top 29%
Diverse Scientific and Economic Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Preliminary Study on Fault Detection in Gas Coolers for Transcritical CO2 Refrigeration Systems · University of Southern Denmark Research Portal (University of Southern Denmark) (2024) | TGRS Research Map | TGRS