Comparative Research on Performances of R516A and R134a in Water-Cooled Chillers

R516A is one of the new substitutes for R134a refrigerant in water-cooled chillers. The COP (coefficient of performance) and discharge temperatures of R516A and R134a are compared through a single-stage vapor compression cycle. Under nominal and variable operating conditions, the performances of a small water-cooled chiller charged with R134a and R516A are tested and compared. The cost changes of replacing R134a with R516A in the water-cooled chiller are discussed. The conclusions indicate that, in the theoretical cycle, the COP of R516A is 1.5% lower than that of R134a, and the discharge temperature is 4.9-6.0 ℃ lower than that of R134a. Under nominal operating conditions, there is a certain performance gap between the R516A chiller and the R134a chiller, with a COP difference of 4.9%-7.2%. Under variable operating conditions, the performance of the R516A chiller is basically equivalent to that of the R134a chiller, and the COP gap is reduced to 0.5%-2.3%. Owing to the mild flammability of R516A, the cost of the R516A chiller is 10%-15% higher than that of the R134a chiller.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Research on Performances of R516A and R134a in Water-Cooled Chillers

SHILAP Revista de lepidopterología
Refrigeration and Air Conditioning Technologies
article

Comparative Research on Performances of R516A and R134a in Water-Cooled Chillers

article en

Abstract

R516A is one of the new substitutes for R134a refrigerant in water-cooled chillers. The COP (coefficient of performance) and discharge temperatures of R516A and R134a are compared through a single-stage vapor compression cycle. Under nominal and variable operating conditions, the performances of a small water-cooled chiller charged with R134a and R516A are tested and compared. The cost changes of replacing R134a with R516A in the water-cooled chiller are discussed. The conclusions indicate that, in the theoretical cycle, the COP of R516A is 1.5% lower than that of R134a, and the discharge temperature is 4.9-6.0 ℃ lower than that of R134a. Under nominal operating conditions, there is a certain performance gap between the R516A chiller and the R134a chiller, with a COP difference of 4.9%-7.2%. Under variable operating conditions, the performance of the R516A chiller is basically equivalent to that of the R134a chiller, and the COP gap is reduced to 0.5%-2.3%. Owing to the mild flammability of R516A, the cost of the R516A chiller is 10%-15% higher than that of the R134a chiller.

SHILAP Revista de lepidopterología
Clean water and sanitation
Openalex Percentile: Top 61%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Research on Performances of R516A and R134a in Water-Cooled Chillers · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS