Capsular Waves: A Warning Indicator for Potentially Malpositioned Intraocular Lenses

J Morgan Micheletti,1 Kendrick M Wang,1,2 Khanh Ton,1 Karlie N Bonem1 1Berkeley Eye Center, Houston, TX, USA; 2Yale University, New Haven, CT, USACorrespondence: J Morgan Micheletti, Berkeley Eye Center, 1435 Hwy 6, Suite #202, Sugar Land, Houston, Texas, 77478, USA, Tel/Fax +1 281-478-9868, Email [email protected]: To share examination findings of the lens capsule which may act as an indicator for malpositioned intraocular lenses (IOL).Setting: Single large multi-specialty private practice, Houston, Texas, USA.Design: Focused, observational case series.Methods: A review of pre-operative images of malpositioned single-piece IOLs with at least one haptic in the ciliary sulcus was conducted. The review included five cases who were referred to a single large multi-specialty private practice from June 2023 to December 2024 for an evaluation of posterior capsular opacification (PCO) and potential Nd:YAG capsulotomy.Findings: A total of five eyes which previously had undergone cataract surgery and were referred for Nd:YAG capsulotomy for PCO were identified on slit lamp examination to have capsular waves, defined as a centripetal and circumferential striated pattern of PCO that results from a fused anterior and posterior capsule with at least part of the IOL anterior to the capsule. While one eye exhibited transillumination defects and pigment dispersion, the remainder of eyes did not. In some cases, the capsular wave was the only clue to IOL malpositioning due to a small pupil. These eyes had single-piece IOLs with at least one haptic in the sulcus and required subsequent IOL repositioning or exchange.Conclusion: If capsular waves are seen on slit lamp exam, a thorough inspection of IOL placement should be conducted, especially before treatment with Nd:YAG capsulotomy. Capsular waves result from anterior and posterior capsule contact with an anteriorly situated IOL. This finding is a potential indicator of at least part of an IOL positioned anterior to the anterior capsule.Keywords: IOL, sulcus, malpositioned IOL, uveitis, glaucoma, hyphema, iris atrophy, transepithelial defect

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Capsular Waves: A Warning Indicator for Potentially Malpositioned Intraocular Lenses

SHILAP Revista de lepidopterología
Intraocular Surgery and Lenses
article

Capsular Waves: A Warning Indicator for Potentially Malpositioned Intraocular Lenses

article en

Abstract

J Morgan Micheletti,1 Kendrick M Wang,1,2 Khanh Ton,1 Karlie N Bonem1 1Berkeley Eye Center, Houston, TX, USA; 2Yale University, New Haven, CT, USACorrespondence: J Morgan Micheletti, Berkeley Eye Center, 1435 Hwy 6, Suite #202, Sugar Land, Houston, Texas, 77478, USA, Tel/Fax +1 281-478-9868, Email [email protected]: To share examination findings of the lens capsule which may act as an indicator for malpositioned intraocular lenses (IOL).Setting: Single large multi-specialty private practice, Houston, Texas, USA.Design: Focused, observational case series.Methods: A review of pre-operative images of malpositioned single-piece IOLs with at least one haptic in the ciliary sulcus was conducted. The review included five cases who were referred to a single large multi-specialty private practice from June 2023 to December 2024 for an evaluation of posterior capsular opacification (PCO) and potential Nd:YAG capsulotomy.Findings: A total of five eyes which previously had undergone cataract surgery and were referred for Nd:YAG capsulotomy for PCO were identified on slit lamp examination to have capsular waves, defined as a centripetal and circumferential striated pattern of PCO that results from a fused anterior and posterior capsule with at least part of the IOL anterior to the capsule. While one eye exhibited transillumination defects and pigment dispersion, the remainder of eyes did not. In some cases, the capsular wave was the only clue to IOL malpositioning due to a small pupil. These eyes had single-piece IOLs with at least one haptic in the sulcus and required subsequent IOL repositioning or exchange.Conclusion: If capsular waves are seen on slit lamp exam, a thorough inspection of IOL placement should be conducted, especially before treatment with Nd:YAG capsulotomy. Capsular waves result from anterior and posterior capsule contact with an anteriorly situated IOL. This finding is a potential indicator of at least part of an IOL positioned anterior to the anterior capsule.Keywords: IOL, sulcus, malpositioned IOL, uveitis, glaucoma, hyphema, iris atrophy, transepithelial defect

SHILAP Revista de lepidopterología
Openalex Percentile: Top 43%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Capsular Waves: A Warning Indicator for Potentially Malpositioned Intraocular Lenses · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS