Вплив корозії елементів першого контуру на розподіл відкладень в циркуляційному тракті реактора SMR 160

The object of research is the circulation path of a water-water small modular reactor. The work is aimed at assessing the influence of corrosion intensity on the formation of sediments on the surfaces of the first circuit of the SMR 160 reactor module. The analysis of the circuit structure was performed, the intensity of corrosion destruction and the intensity of sediments on the local sections of the circuit are evaluated. The circulation circuit of vertical architecture, the movement of the coolant in which excites thermal pressure, created by heating in the core and cooling in the steam generator. The methodology is based on the principle of material balance of the transition of corrosion products into the coolant and their sediment on the circuit surface. To estimate the speed of corrosion the results of complex studies conducted at stations in normal operation and on the physical models of sections of the first circuit in the laboratory were used. Estimation of the speed of sediments is performed according to the ratios that take into account the impact of the concentration of the sedimented substance in the coolant, the thermal load of the site and the consumption of the coolant. The calculations showed that the main source of iron oxides in the circuit is the surface of the steam generator, causing the average value of their concentration in the final areas, and zirconium oxides come from the surface of the core and retain the concentration close to the average along the entire tract. The research results showed that the high corrosion stability of the structural materials of the circuit significantly limits the transition and accumulation of corrosion products in the coolant. In turn, low concentrations of corrosion products in the coolant restrain the formation of their sediments on the surfaces of the core and steam generator. The values of the surface density of sediments and their average thickness are estimated. Analysis of corrosion processes of structural materials and the distribution of their sediments in the circuit allow to predict the level of radiation contamination and to plan the service life of the system. The presented technique allows to evaluate the effectiveness of the water -chemical regime used.

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2025-04-15
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Вплив корозії елементів першого контуру на розподіл відкладень в циркуляційному тракті реактора SMR 160

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Scientific Measurement and Uncertainty Evaluation
article

Вплив корозії елементів першого контуру на розподіл відкладень в циркуляційному тракті реактора SMR 160

article en

Abstract

The object of research is the circulation path of a water-water small modular reactor. The work is aimed at assessing the influence of corrosion intensity on the formation of sediments on the surfaces of the first circuit of the SMR 160 reactor module. The analysis of the circuit structure was performed, the intensity of corrosion destruction and the intensity of sediments on the local sections of the circuit are evaluated. The circulation circuit of vertical architecture, the movement of the coolant in which excites thermal pressure, created by heating in the core and cooling in the steam generator. The methodology is based on the principle of material balance of the transition of corrosion products into the coolant and their sediment on the circuit surface. To estimate the speed of corrosion the results of complex studies conducted at stations in normal operation and on the physical models of sections of the first circuit in the laboratory were used. Estimation of the speed of sediments is performed according to the ratios that take into account the impact of the concentration of the sedimented substance in the coolant, the thermal load of the site and the consumption of the coolant. The calculations showed that the main source of iron oxides in the circuit is the surface of the steam generator, causing the average value of their concentration in the final areas, and zirconium oxides come from the surface of the core and retain the concentration close to the average along the entire tract. The research results showed that the high corrosion stability of the structural materials of the circuit significantly limits the transition and accumulation of corrosion products in the coolant. In turn, low concentrations of corrosion products in the coolant restrain the formation of their sediments on the surfaces of the core and steam generator. The values of the surface density of sediments and their average thickness are estimated. Analysis of corrosion processes of structural materials and the distribution of their sediments in the circuit allow to predict the level of radiation contamination and to plan the service life of the system. The presented technique allows to evaluate the effectiveness of the water -chemical regime used.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Clean water and sanitation
Openalex Percentile: Top 46%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.