Research on the Mechanical Performance and Force Transmission Mechanism of the Hybrid Tower Joint Section in Cable-stayed Bridges Under Eccentric Loading

This study considers the joint segment of the hybrid tower of Qiyun Bridge in Fu'an City as the research object to explore the mechanical characteristics of the hybrid tower joint segment of a cable-stayed bridge under eccentric load. It clarifies the mechanical performance and force transmission mechanism of the joint segment under eccentric load and the reasonable range of parameters affecting the force transmission efficiency using test and numerical analysis. The results indicated that the high safety coefficient, reliable working performance, and low stress level are the main characteristics of the bearing capacity of the hybrid tower joint segment with the rear bearing plate. The stress performance of the joint segment under the action of vertical eccentric load conforms to the force characteristics of eccentric compression components, and the strain is symmetrically distributed in the section. The bearing plate and the shear connector play a vital role in the load transfer, as demonstrated by the strain change of the steel plate (shell) near the bearing plate, and the shear force borne by the shear key near the bearing plate is greater than that of the stud shear key. In addition, the vertical load is effectively transmitted in the joint segment. The transfer efficiency of the load in the joint segment is greatly affected by the thickness of the bearing plate and the shear stiffness of the shear connector. The transfer efficiency increases initially and then tends to stabilize with the increase in the thickness of the bearing plate or the shear stiffness of the shear connector. When the shear key stiffness increases to more than 10 times the original design shear stiffness or the thickness of the bearing plate exceeds 16 mm, the load transfer efficiency remains basically unchanged. In addition, there is an apparent transmission length within the joint segment, which is about 3 m. Beyond this length, the bearing ratio of the steel shell and the filled concrete is basically close to the section stiffness ratioof the joint segment. The steel shell and the concrete, respectively, bear about 50% of the vertical load after the force transfer. The research results provide guidance and reference for the design of similar projects.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Mechanical Performance and Force Transmission Mechanism of the Hybrid Tower Joint Section in Cable-stayed Bridges Under Eccentric Loading

SHILAP Revista de lepidopterología
Vibration and Dynamic Analysis
article

Research on the Mechanical Performance and Force Transmission Mechanism of the Hybrid Tower Joint Section in Cable-stayed Bridges Under Eccentric Loading

article en

Abstract

This study considers the joint segment of the hybrid tower of Qiyun Bridge in Fu'an City as the research object to explore the mechanical characteristics of the hybrid tower joint segment of a cable-stayed bridge under eccentric load. It clarifies the mechanical performance and force transmission mechanism of the joint segment under eccentric load and the reasonable range of parameters affecting the force transmission efficiency using test and numerical analysis. The results indicated that the high safety coefficient, reliable working performance, and low stress level are the main characteristics of the bearing capacity of the hybrid tower joint segment with the rear bearing plate. The stress performance of the joint segment under the action of vertical eccentric load conforms to the force characteristics of eccentric compression components, and the strain is symmetrically distributed in the section. The bearing plate and the shear connector play a vital role in the load transfer, as demonstrated by the strain change of the steel plate (shell) near the bearing plate, and the shear force borne by the shear key near the bearing plate is greater than that of the stud shear key. In addition, the vertical load is effectively transmitted in the joint segment. The transfer efficiency of the load in the joint segment is greatly affected by the thickness of the bearing plate and the shear stiffness of the shear connector. The transfer efficiency increases initially and then tends to stabilize with the increase in the thickness of the bearing plate or the shear stiffness of the shear connector. When the shear key stiffness increases to more than 10 times the original design shear stiffness or the thickness of the bearing plate exceeds 16 mm, the load transfer efficiency remains basically unchanged. In addition, there is an apparent transmission length within the joint segment, which is about 3 m. Beyond this length, the bearing ratio of the steel shell and the filled concrete is basically close to the section stiffness ratioof the joint segment. The steel shell and the concrete, respectively, bear about 50% of the vertical load after the force transfer. The research results provide guidance and reference for the design of similar projects.

SHILAP Revista de lepidopterología
Sustainable cities and communities
Openalex Percentile: Top 45%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.