Ray Visualization and Through-Focus Optical Quality of Diffractive Enhanced Monofocal and Extended-Depth-of-Focus Intraocular Lenses

Isabella Diana Baur,1,2 Ramin Khoramnia,1 Hyeck-Soo Son,1 Gerd Uwe Auffarth,1 Grzegorz Łabuz1 1David J Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany; 2Augsburg University Hospital, Department of Ophthalmology, Augsburg, GermanyCorrespondence: Isabella Diana Baur, Augsburg University Hospital, Department of Ophthalmology, Stenglinstraße 2, Augsburg, 86156, Germany, Email [email protected]: We compared two hybrid refractive-diffractive IOLs with enhanced depth of focus in an in vitro study with regard to optical quality in monochromatic and polychromatic light as well as their ray-propagation behavior.Methods: The Mono-EDoF ME4 IOL (Santen Pharmaceutical, Osaka, Japan) and the Tecnis Symfony IOL (Johnson & Johnson Vision, USA) were assessed using the OptiSpheric IOL PRO 2 (Trioptics GmbH, Germany) to measure the through focus (TF) modulation transfer function (MTF) using monochromatic green (546 nm) and polychromatic light at different spatial frequencies. Ray propagation imaging was performed using monochromatic green light (520 nm) projected through each IOL, while submerged in a bath of fluorescein solution. The visual pathways were captured by a camera mounted on a microscope. Ray visualization was additionally performed for a monofocal control IOL (W60-R IOL, Santen Pharmaceutical).Results: The Mono-EDoF IOL showed superior TF-MTF performance for defocus of up to − 1.3D compared to the Symfony IOL in monochromatic and polychromatic light. For higher defocus values, however, the Symfony showed superior performance than the Mono-EDoF. Image quality in polychromatic light decreased for both IOLs compared to monochromatic light. Ray propagation imaging revealed one distinct focus for the monofocal IOL. The Mono-EDoF demonstrated an elongated focus area. The Symfony showed two focal points.Conclusion: We found comparable deterioration of image quality in polychromatic light for both IOLs with improved intermediate range. The Mono-EDoF demonstrated an elongated focus and superior TF-MTF performance at lower defocus values, but it did not match the standard EDoF model at higher defocus.Keywords: extended depth-of-focus IOL, presbyopia correction, optical bench evaluation

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ray Visualization and Through-Focus Optical Quality of Diffractive Enhanced Monofocal and Extended-Depth-of-Focus Intraocular Lenses

SHILAP Revista de lepidopterología
Ophthalmology and Visual Impairment Studies
article

Ray Visualization and Through-Focus Optical Quality of Diffractive Enhanced Monofocal and Extended-Depth-of-Focus Intraocular Lenses

article en

Abstract

Isabella Diana Baur,1,2 Ramin Khoramnia,1 Hyeck-Soo Son,1 Gerd Uwe Auffarth,1 Grzegorz Łabuz1 1David J Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany; 2Augsburg University Hospital, Department of Ophthalmology, Augsburg, GermanyCorrespondence: Isabella Diana Baur, Augsburg University Hospital, Department of Ophthalmology, Stenglinstraße 2, Augsburg, 86156, Germany, Email [email protected]: We compared two hybrid refractive-diffractive IOLs with enhanced depth of focus in an in vitro study with regard to optical quality in monochromatic and polychromatic light as well as their ray-propagation behavior.Methods: The Mono-EDoF ME4 IOL (Santen Pharmaceutical, Osaka, Japan) and the Tecnis Symfony IOL (Johnson & Johnson Vision, USA) were assessed using the OptiSpheric IOL PRO 2 (Trioptics GmbH, Germany) to measure the through focus (TF) modulation transfer function (MTF) using monochromatic green (546 nm) and polychromatic light at different spatial frequencies. Ray propagation imaging was performed using monochromatic green light (520 nm) projected through each IOL, while submerged in a bath of fluorescein solution. The visual pathways were captured by a camera mounted on a microscope. Ray visualization was additionally performed for a monofocal control IOL (W60-R IOL, Santen Pharmaceutical).Results: The Mono-EDoF IOL showed superior TF-MTF performance for defocus of up to − 1.3D compared to the Symfony IOL in monochromatic and polychromatic light. For higher defocus values, however, the Symfony showed superior performance than the Mono-EDoF. Image quality in polychromatic light decreased for both IOLs compared to monochromatic light. Ray propagation imaging revealed one distinct focus for the monofocal IOL. The Mono-EDoF demonstrated an elongated focus area. The Symfony showed two focal points.Conclusion: We found comparable deterioration of image quality in polychromatic light for both IOLs with improved intermediate range. The Mono-EDoF demonstrated an elongated focus and superior TF-MTF performance at lower defocus values, but it did not match the standard EDoF model at higher defocus.Keywords: extended depth-of-focus IOL, presbyopia correction, optical bench evaluation

SHILAP Revista de lepidopterología
Apple (Israel) (IL)
Openalex Percentile: Top 39%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.