Microchannel Slip Flow Characteristics by Time Travel After Photobleaching Velocimetry

Interfacial science follows the study of observing behavior between two or more phases of matter when in contact. For example, a liquid solution passes through a microchannel, and the walls interact with the fluid shearing along the surface. The fluid particles develop momentum changes from interfacial phenomena and slip along the wall begins to affect the fluid body. Slip flow is a name for the phenomenon, and with it, modeling velocity for the interfacial behavior demands both resolution and minimal interference. Laser-induced fluorescence photobleaching anemometry (LIFPA) works as a sound method for acquiring data on microchannel flow, but it needed precalibration. Building upon the success of LIFPA, measuring the fluorescence of dye between two lasers, time travel after photobleaching velocimetry (TTAPV) has been developed as a calibration free method. This study overviews how slip flow can be measured for a rectangular microchannel. Results for a rectangular microchannel have been produced for near wall conditions. In addition, the use of TTAPV for rectangular microchannels has been evaluated by comparing the results to theoretical modeling. Showing the consistency of TTAPV for different geometries, the study reinforces the viability of TTAPV in the research of interfacial science.

Publication Details

Journal
Scholar Commons (University of South Carolina)
Published
2024-08-19
Primary Topic
Fluid Dynamics and Thin Films
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microchannel Slip Flow Characteristics by Time Travel After Photobleaching Velocimetry

Scholar Commons (University of South Carolina)
Fluid Dynamics and Thin Films
article

Microchannel Slip Flow Characteristics by Time Travel After Photobleaching Velocimetry

article en

Abstract

Interfacial science follows the study of observing behavior between two or more phases of matter when in contact. For example, a liquid solution passes through a microchannel, and the walls interact with the fluid shearing along the surface. The fluid particles develop momentum changes from interfacial phenomena and slip along the wall begins to affect the fluid body. Slip flow is a name for the phenomenon, and with it, modeling velocity for the interfacial behavior demands both resolution and minimal interference. Laser-induced fluorescence photobleaching anemometry (LIFPA) works as a sound method for acquiring data on microchannel flow, but it needed precalibration. Building upon the success of LIFPA, measuring the fluorescence of dye between two lasers, time travel after photobleaching velocimetry (TTAPV) has been developed as a calibration free method. This study overviews how slip flow can be measured for a rectangular microchannel. Results for a rectangular microchannel have been produced for near wall conditions. In addition, the use of TTAPV for rectangular microchannels has been evaluated by comparing the results to theoretical modeling. Showing the consistency of TTAPV for different geometries, the study reinforces the viability of TTAPV in the research of interfacial science.

Scholar Commons (University of South Carolina)
Openalex Percentile: Top 55%
Fluid Dynamics and Thin Films
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microchannel Slip Flow Characteristics by Time Travel After Photobleaching Velocimetry · Scholar Commons (University of South Carolina) (2024) | TGRS Research Map | TGRS