Estimation of skin entrance dose and effective dose in neonates during common radiographic tests in public hospitals in Sari, Iran

Background and Aim: Radiography plays a crucial role in diagnosing neonatal abnormalities. Due to the heightened sensitivity of neonates to ionizing radiation, the small size of their body parts, the proximity of their organs, and their longer life expectancy, there is an increased risk of biological effects from radiation exposure. Therefore, estimating the received radiation dose in neonates is essential. This study aimed to evaluate the skin entrance dose (ESD) and effective dose in neonates admitted to the neonatal intensive care unit (NICU) from common radiographic tests. Methods: In this study, the skin entrance dose (ESD) was measured in 50 neonates in the NICU who underwent chest, abdominal, pelvic, and skull radiography. Air kerma at a distance of one meter from the X-ray tube was measured. The air kerma at the skin entrance site was then calculated, considering the distance from the tube to the film and the thickness of the anatomical region being radiographed. ESD was obtained by multiplying the air kerma by the backscatter factor. Furthermore, the effective dose was computed from the ESD using appropriate conversion factors. Results: The average ESD for chest, abdominal, pelvic, and skull radiographs were 0.3, 0.57, 0.43, and 1.01 milligray (mGy), respectively. The highest effective dose was observed in abdominal and pelvic radiography. Kilovoltage and milliampere-seconds, as the most significant factors affecting ESD, were reported to be 47.2 and 4.8 for chest radiography. The ESD values for chest and abdominal radiographs were higher than international standards, while the ESD values for skull and pelvic radiographs showed no significant difference from the diagnostic reference levels (DRL). Conclusion: The results indicate that neonates received higher doses in chest and abdominal radiographs compared to the standard thresholds. The technical conditions used in these radiographic tests, especially for chest radiography, did not align with the recommended standards. Therefore, reviewing and adjusting imaging techniques for these tests is necessary. Medical imaging centers should select exposure conditions that reduce the effective dose received by neonates while maintaining image quality. It is recommended to use high kilovoltage (kV) and low milliampere (mA) settings for radiography of the neonate's torso (chest, abdomen, and pelvis).

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of skin entrance dose and effective dose in neonates during common radiographic tests in public hospitals in Sari, Iran

SHILAP Revista de lepidopterología
Radiation Dose and Imaging
article

Estimation of skin entrance dose and effective dose in neonates during common radiographic tests in public hospitals in Sari, Iran

article en

Abstract

Background and Aim: Radiography plays a crucial role in diagnosing neonatal abnormalities. Due to the heightened sensitivity of neonates to ionizing radiation, the small size of their body parts, the proximity of their organs, and their longer life expectancy, there is an increased risk of biological effects from radiation exposure. Therefore, estimating the received radiation dose in neonates is essential. This study aimed to evaluate the skin entrance dose (ESD) and effective dose in neonates admitted to the neonatal intensive care unit (NICU) from common radiographic tests. Methods: In this study, the skin entrance dose (ESD) was measured in 50 neonates in the NICU who underwent chest, abdominal, pelvic, and skull radiography. Air kerma at a distance of one meter from the X-ray tube was measured. The air kerma at the skin entrance site was then calculated, considering the distance from the tube to the film and the thickness of the anatomical region being radiographed. ESD was obtained by multiplying the air kerma by the backscatter factor. Furthermore, the effective dose was computed from the ESD using appropriate conversion factors. Results: The average ESD for chest, abdominal, pelvic, and skull radiographs were 0.3, 0.57, 0.43, and 1.01 milligray (mGy), respectively. The highest effective dose was observed in abdominal and pelvic radiography. Kilovoltage and milliampere-seconds, as the most significant factors affecting ESD, were reported to be 47.2 and 4.8 for chest radiography. The ESD values for chest and abdominal radiographs were higher than international standards, while the ESD values for skull and pelvic radiographs showed no significant difference from the diagnostic reference levels (DRL). Conclusion: The results indicate that neonates received higher doses in chest and abdominal radiographs compared to the standard thresholds. The technical conditions used in these radiographic tests, especially for chest radiography, did not align with the recommended standards. Therefore, reviewing and adjusting imaging techniques for these tests is necessary. Medical imaging centers should select exposure conditions that reduce the effective dose received by neonates while maintaining image quality. It is recommended to use high kilovoltage (kV) and low milliampere (mA) settings for radiography of the neonate's torso (chest, abdomen, and pelvis).

SHILAP Revista de lepidopterología
Good health and well-being
Openalex Percentile: Top 44%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.