Comparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems

Sri Ganesh, Sheetal Brar, Supriya Sriganesh, Hemali D Bhavsar Department of Phaco-Refractive Surgery, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, IndiaCorrespondence: Sheetal Brar, Department of Phaco-Refractive surgery, Nethradhama Superspeciality Eye Hospital, Jayanagar, Bengaluru, Karnataka, India, Tel +919591002092, Email [email protected]: To compare the intra-operative surgical performance of Quatera 700 with Centurion and Signature Pro phacoemulsification systems.Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India.Study Design: Prospective, interventional, 3-arm, randomized comparison study.Methods: A total of 180 non-consecutive eyes satisfying the eligibility criteria were recruited. N = 60 eyes were operated using each of the above systems, of which n = 30 eyes had LOCS III grade 1– 2, and n = 30 eyes had grade 3– 4 nuclear density. Phacoemulsification with foldable IOL implantation was performed by a single experienced surgeon. Chamber stability scores (1– 4, 4 being the worst), fluid turnover per case, surge incidence and intra-operative complications were assessed.Results: Intra-operatively, the mean chamber stability score was significantly better for the Quatera 700 in both the soft and dense cataract groups compared to the other two machines (p < 0.001). Total Phaco Time (TPT) with Quatera 700 was significantly lower compared to Signature Pro, while it was comparable with Centurion for both the soft and dense cataract groups. The mean fluid turnover was significantly lower for the Quatera 700 in the dense cataract group (p = 0.04) and so was the combined phaco and I/A time (p = 0.01) when compared with Signature Pro. One eye operated with Signature Pro and 2 eyes operated with Centurion had PCR due to surge. The mean corneal clarity scores on POD-1 and specular counts at 2 weeks and 6 months were comparable.Conclusion: The new Quatera 700 system resulted in lesser TPT, fluid turnover and phaco + I/A time than Signature Pro, while its performance was comparable to Centurion for these parameters. Moreover, the surgeon graded intra-operative chamber stability scoring was highest, when compared to the other two systems.Ctri Registration Number: CTRI/2022/01/039296.Keywords: Quatera 700, Quattro pump, phacoemulsification

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems

SHILAP Revista de lepidopterología
Intraocular Surgery and Lenses
article

Comparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems

article en

Abstract

Sri Ganesh, Sheetal Brar, Supriya Sriganesh, Hemali D Bhavsar Department of Phaco-Refractive Surgery, Nethradhama Super Speciality Eye Hospital, Bengaluru, Karnataka, IndiaCorrespondence: Sheetal Brar, Department of Phaco-Refractive surgery, Nethradhama Superspeciality Eye Hospital, Jayanagar, Bengaluru, Karnataka, India, Tel +919591002092, Email [email protected]: To compare the intra-operative surgical performance of Quatera 700 with Centurion and Signature Pro phacoemulsification systems.Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India.Study Design: Prospective, interventional, 3-arm, randomized comparison study.Methods: A total of 180 non-consecutive eyes satisfying the eligibility criteria were recruited. N = 60 eyes were operated using each of the above systems, of which n = 30 eyes had LOCS III grade 1– 2, and n = 30 eyes had grade 3– 4 nuclear density. Phacoemulsification with foldable IOL implantation was performed by a single experienced surgeon. Chamber stability scores (1– 4, 4 being the worst), fluid turnover per case, surge incidence and intra-operative complications were assessed.Results: Intra-operatively, the mean chamber stability score was significantly better for the Quatera 700 in both the soft and dense cataract groups compared to the other two machines (p < 0.001). Total Phaco Time (TPT) with Quatera 700 was significantly lower compared to Signature Pro, while it was comparable with Centurion for both the soft and dense cataract groups. The mean fluid turnover was significantly lower for the Quatera 700 in the dense cataract group (p = 0.04) and so was the combined phaco and I/A time (p = 0.01) when compared with Signature Pro. One eye operated with Signature Pro and 2 eyes operated with Centurion had PCR due to surge. The mean corneal clarity scores on POD-1 and specular counts at 2 weeks and 6 months were comparable.Conclusion: The new Quatera 700 system resulted in lesser TPT, fluid turnover and phaco + I/A time than Signature Pro, while its performance was comparable to Centurion for these parameters. Moreover, the surgeon graded intra-operative chamber stability scoring was highest, when compared to the other two systems.Ctri Registration Number: CTRI/2022/01/039296.Keywords: Quatera 700, Quattro pump, phacoemulsification

SHILAP Revista de lepidopterología
Openalex Percentile: Top 43%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS