Construction and performance of a 1: 2 scale timber structure under standardized load tests

Timber’s growing prominence in both new construction and heritage rehabilitation demands reliable methods to evaluate structural safety. However, most current load-testing protocols target concrete and overlook key timber-specific characteristics such as creep, delayed deflection, and service classes. This study addresses these gaps by investigating a 1:2 scale two-story timber prototype subjected to monotonic (UNE-EN 380) and cyclic (DAfStb) load tests. A comprehensive array of sensors captured time-dependent deflections and post-unloading recovery, revealing pronounced creep effects and highlighting the limits of existing standards to account for timber’s long-term deformation. Although cyclic tests can be completed more quickly, they do not adequately track delayed deflection behaviour crucial to timber structures; by contrast, the sustained-load protocols demanded by monotonic tests provide meaningful insights into creep and sostenibility considerations (such as water usage). These findings underscore the need to develop updated, consensus-based load-testing guidelines that better reflect timber’s unique mechanical response. Such standards would enable more accurate assessments of timber floors, roofs, and frames in both historic and contemporary contexts.

Publication Details

Journal
Dialnet (Universidad de la Rioja)
Published
2025-01-01
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Construction and performance of a 1: 2 scale timber structure under standardized load tests

Dialnet (Universidad de la Rioja)
Structural Behavior of Reinforced Concrete
article

Construction and performance of a 1: 2 scale timber structure under standardized load tests

article en

Abstract

Timber’s growing prominence in both new construction and heritage rehabilitation demands reliable methods to evaluate structural safety. However, most current load-testing protocols target concrete and overlook key timber-specific characteristics such as creep, delayed deflection, and service classes. This study addresses these gaps by investigating a 1:2 scale two-story timber prototype subjected to monotonic (UNE-EN 380) and cyclic (DAfStb) load tests. A comprehensive array of sensors captured time-dependent deflections and post-unloading recovery, revealing pronounced creep effects and highlighting the limits of existing standards to account for timber’s long-term deformation. Although cyclic tests can be completed more quickly, they do not adequately track delayed deflection behaviour crucial to timber structures; by contrast, the sustained-load protocols demanded by monotonic tests provide meaningful insights into creep and sostenibility considerations (such as water usage). These findings underscore the need to develop updated, consensus-based load-testing guidelines that better reflect timber’s unique mechanical response. Such standards would enable more accurate assessments of timber floors, roofs, and frames in both historic and contemporary contexts.

Dialnet (Universidad de la Rioja)
Universidad de Valladolid, Junta de Castilla y León, European Regional Development Fund
Sustainable cities and communities
Openalex Percentile: Top 50%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.