Avancerade datorsimuleringar av fotonräknande spektral CT för utvärdering av krosstalförvrängningar

Photon-counting computed tomography (PCCT) represents a significant advancement in medical imaging, as it promises higher spatial resolution, spectral imaging capabilities, and reduced radiation dose compared to conventional CT. GE HealthCare is developing an innovative photon-counting detector made of silicon, called the Deep-Silicon Detector, which employs a new edge-on geometry that ensures sufficient detection efficiency. Photoncounting detectors are direct conversion and in general there are no physical barriers between pixels, which allows for crosstalk due to charge sharing and X-ray scattering inside the detector, producing so-called crosstalk artifacts. The Deep-Silicon Detector is equipped with tungsten sheets between the sensors that block cross talk in the slice direction of the detector, but thereare no barriers in the pixel direction. Hence, cross talk remains a major challenge in achieving high-quality reconstructed images and, if not corrected for, poses diffculties from a clinical perspective as well. This thesis focuses on characterizing and explaining the origins of these artifacts, simulating crosstalk inside the detector, and validating the accuracy of the CatSim simulation software, developed by GE HealthCare, in reproducing crosstalk artifacts in clinical images through direct comparison with real images. The work is closely related to the development of a correction algorithm for crosstalk artifacts, as the ability to simulate a phenomenon makes it possible to solve the inverse problem and build such an algorithm. For the simulations, KTH’s supercomputer Dardel was employed, enabling the exploration ofparallelization strategies to optimize the computational effciency of CatSim. The findings confirm that we are able to simulate crosstalk inside the detector, but CatSim can reproduce crosstalk artifacts only to a certain extent. This highlights the need to incorporate more complex phenomena into the simulation before drawing definitive conclusions regarding CatSim’s accuracy and obtaining more realistic artifact representations.

Publication Details

Journal
KTH Publication Database DiVA (KTH Royal Institute of Technology)
Published
2025-01-01
Primary Topic
Agriculture and Agroindustry Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Avancerade datorsimuleringar av fotonräknande spektral CT för utvärdering av krosstalförvrängningar

KTH Publication Database DiVA (KTH Royal Institute of Technology)
Agriculture and Agroindustry Studies
article

Avancerade datorsimuleringar av fotonräknande spektral CT för utvärdering av krosstalförvrängningar

article en

Abstract

Photon-counting computed tomography (PCCT) represents a significant advancement in medical imaging, as it promises higher spatial resolution, spectral imaging capabilities, and reduced radiation dose compared to conventional CT. GE HealthCare is developing an innovative photon-counting detector made of silicon, called the Deep-Silicon Detector, which employs a new edge-on geometry that ensures sufficient detection efficiency. Photoncounting detectors are direct conversion and in general there are no physical barriers between pixels, which allows for crosstalk due to charge sharing and X-ray scattering inside the detector, producing so-called crosstalk artifacts. The Deep-Silicon Detector is equipped with tungsten sheets between the sensors that block cross talk in the slice direction of the detector, but thereare no barriers in the pixel direction. Hence, cross talk remains a major challenge in achieving high-quality reconstructed images and, if not corrected for, poses diffculties from a clinical perspective as well. This thesis focuses on characterizing and explaining the origins of these artifacts, simulating crosstalk inside the detector, and validating the accuracy of the CatSim simulation software, developed by GE HealthCare, in reproducing crosstalk artifacts in clinical images through direct comparison with real images. The work is closely related to the development of a correction algorithm for crosstalk artifacts, as the ability to simulate a phenomenon makes it possible to solve the inverse problem and build such an algorithm. For the simulations, KTH’s supercomputer Dardel was employed, enabling the exploration ofparallelization strategies to optimize the computational effciency of CatSim. The findings confirm that we are able to simulate crosstalk inside the detector, but CatSim can reproduce crosstalk artifacts only to a certain extent. This highlights the need to incorporate more complex phenomena into the simulation before drawing definitive conclusions regarding CatSim’s accuracy and obtaining more realistic artifact representations.

KTH Publication Database DiVA (KTH Royal Institute of Technology)
Industry, innovation and infrastructure
Openalex Percentile: Top 36%
Agriculture and Agroindustry Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.