Accuracy of Gravity-Based Automatic Infusion System for Chemoport Intravenous Infusion

Young Gyu Park,1 Jong-Yeup Kim,2 Dong Won Yang,2 Seungtaek Lee,3 Poomin Park,4 Jong Gwon Choi1 1Department of Oncology-Hematology, Konyang University Hospital, Daejeon, Republic of Korea; 2Department of Biomedical Informatics, College of Medicine, Konyang University, Daejeon, Republic of Korea; 3Department of Gastroenterology, Myongji St. Mary’s Hospital, Seoul, Republic of Korea; 4Aero-Propulsion Division, Korea Aerospace Research Institute, Daejeon, Republic of KoreaCorrespondence: Jong Gwon Choi, Oncology-Hematology, Konyang University Hospital, 158 Gwanjeodong-Ro, Seo-Gu, Daejeon, Republic of Korea, Tel +820426009545, Fax +820426006696, Email [email protected]: An infusion pump designed to deliver a specific volume at a predetermined rate is unable to detect extravasation and may continue infusion despite increased tissue resistance caused by extravasation. Consequently, it is recommended that vesicant drugs, such as chemotherapeutic agents, be administered via gravity infusion to reduce the risk of tissue damage. However, intravenous flow regulators used for gravity infusion have limitations because the infusion rate is influenced by the height, venous pressure, and viscosity of the fluid, which can change with temperature. In this study, we measured the accuracy of Accudrip, a new gravity-based automatic infusion control device designed to correct fluctuating infusion rates.Methods: In 59 cancer patients administered with anticancer drugs, the actual administration rate using Accudrip under various administration conditions and the theoretical administration rate were measured and analyzed 100 times.Results: Comparing the theoretical and actual administration rates using Accudrip confirmed that it can be injected with an average error rate of 4.75%, which clinically demonstrated sufficient accuracy for fluid administration.Conclusion: The gravity-based automatic infusion system showed high accuracy consistent with the theoretical rate of administration even under multiple infusion conditions of cancer patients with chemoport. This system (Accudrip) will greatly contribute to accurate drug administration and minimization of adverse events in real-world hospital settings.Keywords: gravity based automatic infusion system, intravenous infusion, accuracy

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
Primary Topic
Chemotherapy-related skin toxicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Gravity-Based Automatic Infusion System for Chemoport Intravenous Infusion

SHILAP Revista de lepidopterología
Chemotherapy-related skin toxicity
article

Accuracy of Gravity-Based Automatic Infusion System for Chemoport Intravenous Infusion

article en

Abstract

Young Gyu Park,1 Jong-Yeup Kim,2 Dong Won Yang,2 Seungtaek Lee,3 Poomin Park,4 Jong Gwon Choi1 1Department of Oncology-Hematology, Konyang University Hospital, Daejeon, Republic of Korea; 2Department of Biomedical Informatics, College of Medicine, Konyang University, Daejeon, Republic of Korea; 3Department of Gastroenterology, Myongji St. Mary’s Hospital, Seoul, Republic of Korea; 4Aero-Propulsion Division, Korea Aerospace Research Institute, Daejeon, Republic of KoreaCorrespondence: Jong Gwon Choi, Oncology-Hematology, Konyang University Hospital, 158 Gwanjeodong-Ro, Seo-Gu, Daejeon, Republic of Korea, Tel +820426009545, Fax +820426006696, Email [email protected]: An infusion pump designed to deliver a specific volume at a predetermined rate is unable to detect extravasation and may continue infusion despite increased tissue resistance caused by extravasation. Consequently, it is recommended that vesicant drugs, such as chemotherapeutic agents, be administered via gravity infusion to reduce the risk of tissue damage. However, intravenous flow regulators used for gravity infusion have limitations because the infusion rate is influenced by the height, venous pressure, and viscosity of the fluid, which can change with temperature. In this study, we measured the accuracy of Accudrip, a new gravity-based automatic infusion control device designed to correct fluctuating infusion rates.Methods: In 59 cancer patients administered with anticancer drugs, the actual administration rate using Accudrip under various administration conditions and the theoretical administration rate were measured and analyzed 100 times.Results: Comparing the theoretical and actual administration rates using Accudrip confirmed that it can be injected with an average error rate of 4.75%, which clinically demonstrated sufficient accuracy for fluid administration.Conclusion: The gravity-based automatic infusion system showed high accuracy consistent with the theoretical rate of administration even under multiple infusion conditions of cancer patients with chemoport. This system (Accudrip) will greatly contribute to accurate drug administration and minimization of adverse events in real-world hospital settings.Keywords: gravity based automatic infusion system, intravenous infusion, accuracy

SHILAP Revista de lepidopterología
Electric Propulsion Laboratory (United States) (US)
Good health and well-being
Openalex Percentile: Top 31%
Chemotherapy-related skin toxicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of Gravity-Based Automatic Infusion System for Chemoport Intravenous Infusion · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS