内部構造を木質化した建築物の延焼防止性能検証
Case study on an office building is conducted using a novel performance-based method for verifying compatibility of fire spread prevention performance of a building with that required by the building standard law. In order to relax the restriction on the fire-resistive performance of the inner wall and floor to be equivalent to the quasi-fire-resistive construction of 45 minutes, it is necessary not only to improve the fire-resistive performance of the external wall and window, but also to subdivide the inner space into several fire compartments.
Publication Details
- Journal
- Tokyo Tech Research Repository (Tokyo Institute of Technology)
- Published
- 2025-04-29
- Primary Topic
- Education, Safety, and Science Studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00