多回線直流送電における低速直流遮断器の適用可能性の検討―制限電圧の緩和によるアレスタ消費エネルギーの低減―

Multi-circuit HVDC transmission systems have the advantage of achieving continuous operation after DC faults even with low-speed DC circuit breakers. However, there was a problem of excessive energy consumption of arresters used for overvoltage suppression. This paper proposes a design approach to mitigate the rated voltage of the arresters as a solution. The effectiveness of this approach is verified through simulation. Assuming acceptance of temporary overvoltage (TOV) equivalent to that in AC systems, the proposed approach can reduce the energy consumption of the arresters to 40% of the conventional design. The approach also shows effectiveness in lowering the overload requirements for diodes in onshore converters and the maximum interruption current requirements for DC circuit breakers.

Publication Details

Journal
Tokyo Tech Research Repository (Tokyo Institute of Technology)
Published
2024-11-12
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

多回線直流送電における低速直流遮断器の適用可能性の検討―制限電圧の緩和によるアレスタ消費エネルギーの低減―

Tokyo Tech Research Repository (Tokyo Institute of Technology)
HVDC Systems and Fault Protection
article

多回線直流送電における低速直流遮断器の適用可能性の検討―制限電圧の緩和によるアレスタ消費エネルギーの低減―

article en

Abstract

Multi-circuit HVDC transmission systems have the advantage of achieving continuous operation after DC faults even with low-speed DC circuit breakers. However, there was a problem of excessive energy consumption of arresters used for overvoltage suppression. This paper proposes a design approach to mitigate the rated voltage of the arresters as a solution. The effectiveness of this approach is verified through simulation. Assuming acceptance of temporary overvoltage (TOV) equivalent to that in AC systems, the proposed approach can reduce the energy consumption of the arresters to 40% of the conventional design. The approach also shows effectiveness in lowering the overload requirements for diodes in onshore converters and the maximum interruption current requirements for DC circuit breakers.

Tokyo Tech Research Repository (Tokyo Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 64%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

多回線直流送電における低速直流遮断器の適用可能性の検討―制限電圧の緩和によるアレスタ消費エネルギーの低減― · Tokyo Tech Research Repository (Tokyo Institute of Technology) (2024) | TGRS Research Map | TGRS