ПАРАМЕТРИ ТЕПЛООБМІННИКІВ ГАРЯЧОГО ВОДОПОСТАЧАННЯ ДЛЯ ТЕПЛОВИХ ПУНКТІВ УТЕПЛЕНИХ БУДІВЕЛЬ ПРИ ОДНОСТУПІНЧАСТІЙ СХЕМІ ПРИЄДНАННЯ

The peculiarities of functioning of centralized heat supply systems of residential microdistricts at carrying out works on ‘insulation’ of buildings in operation, namely, parameters of operation of hot water supply heating units are considered. The influence of the heating load reduction due to the works on increasing the heat transfer resistance of the building structures on the flow rate of network water and heat exchange area of hot water supply heaters has been analyzed. Estimates are made for conditions of use of one-stage parallel scheme connection for heat exchangers to heat distribution networks. The known relations for such most widespread in heat supply systems heat exchangers as plate apparatuses are used at calculations of a heat transfer surface. The range of change of the heat transfer surface of hot water heaters and the flow rate of network water depending on the ratio of the maximum heat loads of hot water supply and heating and the degree of insulation efficiency of the building is determined. Formulas for determining the parameters of hot water supply heat exchangers are proposed. The formulas are valid in the range of reduction of heat consumption for heating of the building from 0 to 35 %. Assessment of the heating load reduction is performed on condition that the thermal modernization of a building constructed in accordance with the building requirements in force several decades ago provides modern requirements for the thermal resistance of building structures. The temperature of water in the heating system of the insulated building is determined depending on the building insulation efficiency, provided that the water flow rate through the heating system of the building before and after its insulation is unchanged. The range of variation of the ratio of hot water supply and heating heat loads accepted for consideration is 0,6–1,2. The obtained results can be used at comparison of connection schemes of heat exchangers for hot water heating for installation on individual heat points of insulated buildings. Keywords: district heating; reforming of heat supply systems; individual heat station; hot water heaters; single-stage scheme of heat exchangers connection; heat transfer surface area, flow rate of network water for hot water supply.

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2024-12-30
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ПАРАМЕТРИ ТЕПЛООБМІННИКІВ ГАРЯЧОГО ВОДОПОСТАЧАННЯ ДЛЯ ТЕПЛОВИХ ПУНКТІВ УТЕПЛЕНИХ БУДІВЕЛЬ ПРИ ОДНОСТУПІНЧАСТІЙ СХЕМІ ПРИЄДНАННЯ

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Geothermal Energy Systems and Applications
article

ПАРАМЕТРИ ТЕПЛООБМІННИКІВ ГАРЯЧОГО ВОДОПОСТАЧАННЯ ДЛЯ ТЕПЛОВИХ ПУНКТІВ УТЕПЛЕНИХ БУДІВЕЛЬ ПРИ ОДНОСТУПІНЧАСТІЙ СХЕМІ ПРИЄДНАННЯ

article en

Abstract

The peculiarities of functioning of centralized heat supply systems of residential microdistricts at carrying out works on ‘insulation’ of buildings in operation, namely, parameters of operation of hot water supply heating units are considered. The influence of the heating load reduction due to the works on increasing the heat transfer resistance of the building structures on the flow rate of network water and heat exchange area of hot water supply heaters has been analyzed. Estimates are made for conditions of use of one-stage parallel scheme connection for heat exchangers to heat distribution networks. The known relations for such most widespread in heat supply systems heat exchangers as plate apparatuses are used at calculations of a heat transfer surface. The range of change of the heat transfer surface of hot water heaters and the flow rate of network water depending on the ratio of the maximum heat loads of hot water supply and heating and the degree of insulation efficiency of the building is determined. Formulas for determining the parameters of hot water supply heat exchangers are proposed. The formulas are valid in the range of reduction of heat consumption for heating of the building from 0 to 35 %. Assessment of the heating load reduction is performed on condition that the thermal modernization of a building constructed in accordance with the building requirements in force several decades ago provides modern requirements for the thermal resistance of building structures. The temperature of water in the heating system of the insulated building is determined depending on the building insulation efficiency, provided that the water flow rate through the heating system of the building before and after its insulation is unchanged. The range of variation of the ratio of hot water supply and heating heat loads accepted for consideration is 0,6–1,2. The obtained results can be used at comparison of connection schemes of heat exchangers for hot water heating for installation on individual heat points of insulated buildings. Keywords: district heating; reforming of heat supply systems; individual heat station; hot water heaters; single-stage scheme of heat exchangers connection; heat transfer surface area, flow rate of network water for hot water supply.

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Sustainable cities and communities
Openalex Percentile: Top 71%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.