Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Trifocal Diffractive Intraocular Lens

Javier Mendicute,1,2 Gorka Lauzirika,1,3 Igor Illarramendi,1 Itziar Martínez-Soroa1,2 1Miranza Begitek, Donostia - San Sebastián, 20012, Spain; 2Donostia University Hospital, Donostia - San Sebastián, 20014, Spain; 3R&D Department of Miranza Group, Donostia - San Sebastián, SpainCorrespondence: Gorka Lauzirika, Miranza Begitek, Teresa Calcutta Square, No. 7, Donostia - San Sebastián, 20012, Spain, Email [email protected]: To describe the visual, refractive, functional, and patient satisfaction outcomes of the Clareon® PanOptix® trifocal intraocular lens (IOL).Patients and Methods: This was a prospective longitudinal descriptive study. Patients who underwent cataract surgery with implantation of Clareon® PanOptix® (Alcon Laboratories, Inc.) were included. Monocular refractive outcomes and visual acuity at distance, intermediate, and near were evaluated 1- and 6-months post-op. Binocular contrast sensitivity (M&S® Technologies), binocular defocus curve, and patient satisfaction with the IOL Satisfaction (IOLSAT) and Questionnaire for Visual Disturbance (QUVID) questionaries were assessed at 6-month post-op.Results: Seventy-six Clareon® PanOptix® were implanted bilaterally in 38 patients. The mean age of the patients was 67.63± 5.18 years. At 1-month post-op, the monocular Corrected Distance Visual Acuity (CDVA), CIVA and CNVA were 0.00± 0.09, 0.02± 0.17, and 0.12± 0.12 LogMAR, respectively, and CDVA and CNVA were stable at 6-month post-op (p> 0.05). No statistical differences were found in post-op spherical equivalent at 1 and 6 months (− 0.08± 0.27 D and − 0.05± 0.24 D; p=0.351). A 100% of eyes were within ± 0.5 D at 1 month and 6-month post-op. Binocular defocus curve shows three peaks of maximum visual acuity (VA) at 0D (− 0.04± 0.08 LogMAR), at − 1.50D, and − 2.50 D (0.01± 0.10 LogMAR and 0.03± 0.07 LogMAR, respectively). Contrast sensitivity decreased at high spatial frequencies. In patient satisfaction, IOLSAT questionary reveals 78.94% patients “Never” or “Rarely” Needing Glasses and according QUVID questionnaire, 100% of patients report no hazy vision.Conclusion: The PanOptix® IOL platform with the new material Clareon® provides good visual outcomes for distance, intermediate, and near vision, with adequate contrast sensitivity and low visual disturbances.Keywords: cataract surgery, multifocal lens, vision restoration, phacoemulsification

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Trifocal Diffractive Intraocular Lens

SHILAP Revista de lepidopterología
Ophthalmology and Visual Impairment Studies
article

Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Trifocal Diffractive Intraocular Lens

article en

Abstract

Javier Mendicute,1,2 Gorka Lauzirika,1,3 Igor Illarramendi,1 Itziar Martínez-Soroa1,2 1Miranza Begitek, Donostia - San Sebastián, 20012, Spain; 2Donostia University Hospital, Donostia - San Sebastián, 20014, Spain; 3R&D Department of Miranza Group, Donostia - San Sebastián, SpainCorrespondence: Gorka Lauzirika, Miranza Begitek, Teresa Calcutta Square, No. 7, Donostia - San Sebastián, 20012, Spain, Email [email protected]: To describe the visual, refractive, functional, and patient satisfaction outcomes of the Clareon® PanOptix® trifocal intraocular lens (IOL).Patients and Methods: This was a prospective longitudinal descriptive study. Patients who underwent cataract surgery with implantation of Clareon® PanOptix® (Alcon Laboratories, Inc.) were included. Monocular refractive outcomes and visual acuity at distance, intermediate, and near were evaluated 1- and 6-months post-op. Binocular contrast sensitivity (M&S® Technologies), binocular defocus curve, and patient satisfaction with the IOL Satisfaction (IOLSAT) and Questionnaire for Visual Disturbance (QUVID) questionaries were assessed at 6-month post-op.Results: Seventy-six Clareon® PanOptix® were implanted bilaterally in 38 patients. The mean age of the patients was 67.63± 5.18 years. At 1-month post-op, the monocular Corrected Distance Visual Acuity (CDVA), CIVA and CNVA were 0.00± 0.09, 0.02± 0.17, and 0.12± 0.12 LogMAR, respectively, and CDVA and CNVA were stable at 6-month post-op (p> 0.05). No statistical differences were found in post-op spherical equivalent at 1 and 6 months (− 0.08± 0.27 D and − 0.05± 0.24 D; p=0.351). A 100% of eyes were within ± 0.5 D at 1 month and 6-month post-op. Binocular defocus curve shows three peaks of maximum visual acuity (VA) at 0D (− 0.04± 0.08 LogMAR), at − 1.50D, and − 2.50 D (0.01± 0.10 LogMAR and 0.03± 0.07 LogMAR, respectively). Contrast sensitivity decreased at high spatial frequencies. In patient satisfaction, IOLSAT questionary reveals 78.94% patients “Never” or “Rarely” Needing Glasses and according QUVID questionnaire, 100% of patients report no hazy vision.Conclusion: The PanOptix® IOL platform with the new material Clareon® provides good visual outcomes for distance, intermediate, and near vision, with adequate contrast sensitivity and low visual disturbances.Keywords: cataract surgery, multifocal lens, vision restoration, phacoemulsification

SHILAP Revista de lepidopterología
Openalex Percentile: Top 44%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Trifocal Diffractive Intraocular Lens · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS