Spatial Resolution Analysis of Laboratory-Based X-ray Imaging System : Evaluation using pinhole and edge method

This study evaluates the spatial resolution of a laboratory-based Xray imaging system using two established methods: edge analysis and pinhole imaging. The edge method involves extraction the Edge Spread Function (ESF), computing the Line Spread Function (LSF), and deriving the Modulation Transfer Function (MTF) to assess detector-limited performance. The pinhole method used a small aperture to approximate a point source, from which the Point Spread Function (PSF) is obtained and modelled using a twodimensional Gaussian fit.The results from the edge method showed high consistency, with a MTF50 of approximately 0,755 lp/mm and a Full Width at Half Maximum (FWHM) of around 0,54 mm. These values are in good agreement with the detector manufacturer’s specifications. The pinhole method yielded significantly broader PSF, with a much lower MTF50 of approximately 0,0003 lp/mm, reflecting the full system blur including geometric and source contributions. The study concludes that both methods offer complementary perspectives: the edge method accurately measures the detectors resolution, while the pinhole method provides insight into the total system performance. The results contribute to quality assurance practices and support future system optimization.

Publication Details

Journal
Publications (Mid Sweden University)
Published
2025-01-01
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatial Resolution Analysis of Laboratory-Based X-ray Imaging System : Evaluation using pinhole and edge method

Publications (Mid Sweden University)
Digital Radiography and Breast Imaging
article

Spatial Resolution Analysis of Laboratory-Based X-ray Imaging System : Evaluation using pinhole and edge method

article en

Abstract

This study evaluates the spatial resolution of a laboratory-based Xray imaging system using two established methods: edge analysis and pinhole imaging. The edge method involves extraction the Edge Spread Function (ESF), computing the Line Spread Function (LSF), and deriving the Modulation Transfer Function (MTF) to assess detector-limited performance. The pinhole method used a small aperture to approximate a point source, from which the Point Spread Function (PSF) is obtained and modelled using a twodimensional Gaussian fit.The results from the edge method showed high consistency, with a MTF50 of approximately 0,755 lp/mm and a Full Width at Half Maximum (FWHM) of around 0,54 mm. These values are in good agreement with the detector manufacturer’s specifications. The pinhole method yielded significantly broader PSF, with a much lower MTF50 of approximately 0,0003 lp/mm, reflecting the full system blur including geometric and source contributions. The study concludes that both methods offer complementary perspectives: the edge method accurately measures the detectors resolution, while the pinhole method provides insight into the total system performance. The results contribute to quality assurance practices and support future system optimization.

Publications (Mid Sweden University)
Industry, innovation and infrastructure
Openalex Percentile: Top 35%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Spatial Resolution Analysis of Laboratory-Based X-ray Imaging System : Evaluation using pinhole and edge method · Publications (Mid Sweden University) (2025) | TGRS Research Map | TGRS