Point of care microfluidic tool development for in-vitro diagnostics

The device, still at the mock-up stage, on which this Master’s thesis project is based, aims to improve medical diagnosis by offering a portable, rapid and accessible solution capable of providing haematological analyses directly at the point-of-care. This mock-up of an innovative haematology machine includes microtechnologies and a reusable microfluidic cartridge in which blood tests are carried out. Despite the progress made in medical diagnostics, current haematology analysers remain bulky, expensive and often inaccessible in regions with limited resources. Responding to major societal challenges such as universal access to affordable, high-quality healthcare solutions, in line with the United Nations’ Sustainable Development Goals, this project aims for future industrialisation, which would represent a significant advance in the medical field and innovation in healthcare.Although promising, this portable machine still faces a number of technical challenges that need to be addressed before it can be considered for industrialisation. The methodological approach adopted is based on mostly iterative experimental investigations: the malfunctions observed led to the implementation of successive modifications. These adjustments were then evaluated through repeatability tests to validate their effectiveness and eliminate the initial problems.The main results concern investigations and improvements relating to three major aspects: fluid transfer, cleaning of the reusable cartridge and improvement of analysis cycles. Numerical simulation work focused on identifying and resolving fluid transfer problems inside the microfluidic cartridge during shutdown of the mock-up. This led to the implementation of modifications that reduced fluid transfer, thereby limiting the risk of pollution of the various reagents, a crucial factor for accurate blood analysis. In addition, the cleaning protocol for the reusable microfluidic cartridge was improved, helping to maintain the cartridge’s long-term usability while reducing the risk of contamination between analyses. Finally, modifications were made to certain blood cells counting cycles. By working on the amount of reagents used, analysis cycles have been stabilised, guaranteeing accurate blood cell counts.All the improvement actions implemented during my Master’s thesis, although limited in time, have enabled the continuous development of the mock-up onthe points mentioned above, while identifying some areas for optimisation at later stages before its industrialisation. Thus, it is proposed to investigate points such as blood sample collection and the reproducibility of haematological performance under different environmental conditions. This project illustrâtes the potential of emerging technologies to have a sustainable impact on medical diagnosis, as close as possible to the patients’ needs.

Publication Details

Journal
KTH Publication Database DiVA (KTH Royal Institute of Technology)
Published
2025-01-01
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Point of care microfluidic tool development for in-vitro diagnostics

KTH Publication Database DiVA (KTH Royal Institute of Technology)
Biosensors and Analytical Detection
article

Point of care microfluidic tool development for in-vitro diagnostics

article en

Abstract

The device, still at the mock-up stage, on which this Master’s thesis project is based, aims to improve medical diagnosis by offering a portable, rapid and accessible solution capable of providing haematological analyses directly at the point-of-care. This mock-up of an innovative haematology machine includes microtechnologies and a reusable microfluidic cartridge in which blood tests are carried out. Despite the progress made in medical diagnostics, current haematology analysers remain bulky, expensive and often inaccessible in regions with limited resources. Responding to major societal challenges such as universal access to affordable, high-quality healthcare solutions, in line with the United Nations’ Sustainable Development Goals, this project aims for future industrialisation, which would represent a significant advance in the medical field and innovation in healthcare.Although promising, this portable machine still faces a number of technical challenges that need to be addressed before it can be considered for industrialisation. The methodological approach adopted is based on mostly iterative experimental investigations: the malfunctions observed led to the implementation of successive modifications. These adjustments were then evaluated through repeatability tests to validate their effectiveness and eliminate the initial problems.The main results concern investigations and improvements relating to three major aspects: fluid transfer, cleaning of the reusable cartridge and improvement of analysis cycles. Numerical simulation work focused on identifying and resolving fluid transfer problems inside the microfluidic cartridge during shutdown of the mock-up. This led to the implementation of modifications that reduced fluid transfer, thereby limiting the risk of pollution of the various reagents, a crucial factor for accurate blood analysis. In addition, the cleaning protocol for the reusable microfluidic cartridge was improved, helping to maintain the cartridge’s long-term usability while reducing the risk of contamination between analyses. Finally, modifications were made to certain blood cells counting cycles. By working on the amount of reagents used, analysis cycles have been stabilised, guaranteeing accurate blood cell counts.All the improvement actions implemented during my Master’s thesis, although limited in time, have enabled the continuous development of the mock-up onthe points mentioned above, while identifying some areas for optimisation at later stages before its industrialisation. Thus, it is proposed to investigate points such as blood sample collection and the reproducibility of haematological performance under different environmental conditions. This project illustrâtes the potential of emerging technologies to have a sustainable impact on medical diagnosis, as close as possible to the patients’ needs.

KTH Publication Database DiVA (KTH Royal Institute of Technology)
Industry, innovation and infrastructure
Openalex Percentile: Top 53%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.