Intermittent Use of Flash Glucose Monitoring Improves Glycemic Control in Chinese Older Patients with Type 2 Diabetes Mellitus

Yonghui Hu,&ast; Rengna Yan,&ast; Yun Shen, Huiqin Li, Jianhua Ma, Xiaofei Su Department of Endocrinology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210012, People’s Republic of China&ast;These authors contributed equally to this workCorrespondence: Jianhua Ma; Xiaofei Su, Email [email protected]; [email protected]: To explore the efficacy and safety of intermittent use of flash glucose monitoring (FGM) for improving glycemic control in Chinese elderly patients with type 2 diabetes mellitus (T2DM).Methods: This is a prospective observational study involving patients with T2DM aged ≥ 60 years. The study period spans 12 weeks, with participants wearing FGM at weeks 0, 5, and 10. Participants were divided into two subgroups based on HbA1c at enrollment: < 7.0% and ≥ 7.0%. The primary outcome of the study was HbA1c level. Secondary outcomes included time in range (3.9– 10mmol/L) (TIR), time below range (< 3.9mmol/L) (TBR), time above range (> 10.0mmol/L) (TAR), and glycemic variability (GV).Results: A total of 68 patients completed the 12-week FGM follow-up (age 67.9 ± 5.2 years; BMI 25.4 ± 3.3kg/m²). Overall findings revealed that compared to baseline, HbA1c decreased from 7.81 ± 1.25% to 7.44± 1.10% after 12 weeks of intermittent wearing of FGM (p < 0.001). In the subgroup analysis with HbA1c ≥ 7.0%, the results showed a significant reduction in HbA1c of 0.51mmol/L after 12 weeks (8.36 ± 0.95% vs 7.75 ± 0.97%, p < 0.001). And there was a significant reduction in TBR in the subgroup with HbA1c < 7% (p = 0.028). Multiple linear regression analysis showed that the baseline HbA1c (β = − 0.529, P< 0.001), duration of T2DM (β = 0.341, P = 0.001), and the frequency of sensor use (β = − 0.269, P = 0.043) were associated with the reduction in HbA1c level.Conclusion: Intermittent use of FGM is associated with an improvement in glycemic outcomes and reduces the risk of hypoglycemia in Chinese elderly patients with T2DM.Keywords: flash glucose monitoring, type 2 diabetes mellitus, HbA1c, time in range

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-01-01
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intermittent Use of Flash Glucose Monitoring Improves Glycemic Control in Chinese Older Patients with Type 2 Diabetes Mellitus

SHILAP Revista de lepidopterología
Diabetes Management and Research
article

Intermittent Use of Flash Glucose Monitoring Improves Glycemic Control in Chinese Older Patients with Type 2 Diabetes Mellitus

article en

Abstract

Yonghui Hu,&ast; Rengna Yan,&ast; Yun Shen, Huiqin Li, Jianhua Ma, Xiaofei Su Department of Endocrinology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210012, People’s Republic of China&ast;These authors contributed equally to this workCorrespondence: Jianhua Ma; Xiaofei Su, Email [email protected]; [email protected]: To explore the efficacy and safety of intermittent use of flash glucose monitoring (FGM) for improving glycemic control in Chinese elderly patients with type 2 diabetes mellitus (T2DM).Methods: This is a prospective observational study involving patients with T2DM aged ≥ 60 years. The study period spans 12 weeks, with participants wearing FGM at weeks 0, 5, and 10. Participants were divided into two subgroups based on HbA1c at enrollment: < 7.0% and ≥ 7.0%. The primary outcome of the study was HbA1c level. Secondary outcomes included time in range (3.9– 10mmol/L) (TIR), time below range (< 3.9mmol/L) (TBR), time above range (> 10.0mmol/L) (TAR), and glycemic variability (GV).Results: A total of 68 patients completed the 12-week FGM follow-up (age 67.9 ± 5.2 years; BMI 25.4 ± 3.3kg/m²). Overall findings revealed that compared to baseline, HbA1c decreased from 7.81 ± 1.25% to 7.44± 1.10% after 12 weeks of intermittent wearing of FGM (p < 0.001). In the subgroup analysis with HbA1c ≥ 7.0%, the results showed a significant reduction in HbA1c of 0.51mmol/L after 12 weeks (8.36 ± 0.95% vs 7.75 ± 0.97%, p < 0.001). And there was a significant reduction in TBR in the subgroup with HbA1c < 7% (p = 0.028). Multiple linear regression analysis showed that the baseline HbA1c (β = − 0.529, P< 0.001), duration of T2DM (β = 0.341, P = 0.001), and the frequency of sensor use (β = − 0.269, P = 0.043) were associated with the reduction in HbA1c level.Conclusion: Intermittent use of FGM is associated with an improvement in glycemic outcomes and reduces the risk of hypoglycemia in Chinese elderly patients with T2DM.Keywords: flash glucose monitoring, type 2 diabetes mellitus, HbA1c, time in range

SHILAP Revista de lepidopterología
Openalex Percentile: Top 40%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Intermittent Use of Flash Glucose Monitoring Improves Glycemic Control in Chinese Older Patients with Type 2 Diabetes Mellitus · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS