Influence of Electronic Expansion Valve Opening on Performance of Constant-Temperature and -Humidity Cabinets

The regulation of the throttling device has an important impact on the performance of constant-temperature and humidity cabinets. Based on a constant-frequency refrigeration system, the effects of EEV (electronic expansion valve) opening from 10% to 30% on the evaporator superheat, compressor discharge temperature, evaporator fin temperature, and temperature and humidity in the cabinet under different target conditions were experimentally studied. When the opening of the electronic expansion valve is 15%-30%, the superheat (8-15 ℃) and discharge temperature can be guaranteed in safe and reasonable ranges. When the opening of the electronic expansion valve is below 20%, a bypass capillary tube is set for a safe compressor operation with liquid cooling in suction. Under the conditions of low temperature and humidity and high temperature and humidity, the larger opening reduces the temperature and humidity adjustment time by 10-20 min. Under the conditions of a low temperature and high humidity and a high temperature and low humidity, the larger opening causes energy consumption for additional humidity compensation or thermal compensation and prolongs the temperature and humidity adjustment time. Under different target conditions, the relative humidity and dry bulb temperature in the small opening (15%) cabinet are closer to the target temperature and humidity than those for the large opening (25%, 30%), and the temperature and humidity control accuracy is higher.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Electronic Expansion Valve Opening on Performance of Constant-Temperature and -Humidity Cabinets

SHILAP Revista de lepidopterología
Refrigeration and Air Conditioning Technologies
article

Influence of Electronic Expansion Valve Opening on Performance of Constant-Temperature and -Humidity Cabinets

article en

Abstract

The regulation of the throttling device has an important impact on the performance of constant-temperature and humidity cabinets. Based on a constant-frequency refrigeration system, the effects of EEV (electronic expansion valve) opening from 10% to 30% on the evaporator superheat, compressor discharge temperature, evaporator fin temperature, and temperature and humidity in the cabinet under different target conditions were experimentally studied. When the opening of the electronic expansion valve is 15%-30%, the superheat (8-15 ℃) and discharge temperature can be guaranteed in safe and reasonable ranges. When the opening of the electronic expansion valve is below 20%, a bypass capillary tube is set for a safe compressor operation with liquid cooling in suction. Under the conditions of low temperature and humidity and high temperature and humidity, the larger opening reduces the temperature and humidity adjustment time by 10-20 min. Under the conditions of a low temperature and high humidity and a high temperature and low humidity, the larger opening causes energy consumption for additional humidity compensation or thermal compensation and prolongs the temperature and humidity adjustment time. Under different target conditions, the relative humidity and dry bulb temperature in the small opening (15%) cabinet are closer to the target temperature and humidity than those for the large opening (25%, 30%), and the temperature and humidity control accuracy is higher.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 61%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.