Electric Pulp Tester Response Thresholds Across Electrode Placement Sites in Maxillary and Mandibular Anterior Teeth: A Cross-Sectional Study

OBJECTIVES To compare the Electric Pulp Tester (EPT) response thresholds at different electrode placement sites (incisal edge, third, middle third, and cervical third) in maxillary and mandibular anterior teeth. METHODOLOGY This cross-sectional study was carried out from December 2022 to March 2023. This study included individuals from the age range of 18 – 60 years. Six teeth of 60 individuals were assessed in the study. Randomly, either the right or left side of the arch was selected. EPT was performed on each tooth at four different sites (incisal edge, incisal third, middle third, cervical third, labially). The reading was noted when the individual felt tingling or warmth in the tooth. The digital readout at which the participant felt the sensation was considered the threshold. The data was analyzed using R/RStudio. Means of variables from each location were compared using ANOVA and Pair sample t Test while the critical level of significance was set at p ≤ 0.05. RESULTS No statistically significant differences were observed in EPT readings between maxillary and mandibular teeth across the tested regions (p > 0.05). In maxillary anterior teeth, significant differences were found across the four areas, with the middle third of central and lateral incisors (15.77 ± 8.13, p = 0.045; 16.30 ± 8.70, p = 0.032) and the cervical third of canines (17.58 ± 10.76, p = 0.028) showing the lowest threshold values. In contrast, no significant variations were observed in the mandibular anterior teeth across the four regions (p > 0.05). CONCLUSION The middle third of maxillary anterior teeth may be an optimal site for EPT electrode placement. However, no significant differences were noted across regions for mandibular anterior teeth.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electric Pulp Tester Response Thresholds Across Electrode Placement Sites in Maxillary and Mandibular Anterior Teeth: A Cross-Sectional Study

SHILAP Revista de lepidopterología
Endodontics and Root Canal Treatments
article

Electric Pulp Tester Response Thresholds Across Electrode Placement Sites in Maxillary and Mandibular Anterior Teeth: A Cross-Sectional Study

article en

Abstract

OBJECTIVES To compare the Electric Pulp Tester (EPT) response thresholds at different electrode placement sites (incisal edge, third, middle third, and cervical third) in maxillary and mandibular anterior teeth. METHODOLOGY This cross-sectional study was carried out from December 2022 to March 2023. This study included individuals from the age range of 18 – 60 years. Six teeth of 60 individuals were assessed in the study. Randomly, either the right or left side of the arch was selected. EPT was performed on each tooth at four different sites (incisal edge, incisal third, middle third, cervical third, labially). The reading was noted when the individual felt tingling or warmth in the tooth. The digital readout at which the participant felt the sensation was considered the threshold. The data was analyzed using R/RStudio. Means of variables from each location were compared using ANOVA and Pair sample t Test while the critical level of significance was set at p ≤ 0.05. RESULTS No statistically significant differences were observed in EPT readings between maxillary and mandibular teeth across the tested regions (p > 0.05). In maxillary anterior teeth, significant differences were found across the four areas, with the middle third of central and lateral incisors (15.77 ± 8.13, p = 0.045; 16.30 ± 8.70, p = 0.032) and the cervical third of canines (17.58 ± 10.76, p = 0.028) showing the lowest threshold values. In contrast, no significant variations were observed in the mandibular anterior teeth across the four regions (p > 0.05). CONCLUSION The middle third of maxillary anterior teeth may be an optimal site for EPT electrode placement. However, no significant differences were noted across regions for mandibular anterior teeth.

SHILAP Revista de lepidopterología
Khyber Medical College (PK)
Quality Education
Openalex Percentile: Top 38%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electric Pulp Tester Response Thresholds Across Electrode Placement Sites in Maxillary and Mandibular Anterior Teeth: A Cross-Sectional Study · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS