Dose-Volume Constraints Parameters for Lung Tissue in Thoracic Radiotherapy Following Immune Checkpoint Inhibitor Treatment

Kang Wang,1 Fengchang Yang,1 Changxing Feng,1 Fuhao Xu,1 Li Li,1 Jinghao Duan,1 Shuanghu Yuan1,2 1Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, People’s Republic of China; 2Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, People’s Republic of ChinaCorrespondence: Shuanghu Yuan, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No. 440 Jiyan Road, Jinan, Shandong, 250117, People’s Republic of China, Tel +86-531-67626931, Fax +86-531-87984079, Email [email protected]: This study aims to identify risk factors associated with symptomatic radiation pneumonitis (RP, Grade ≥ 2) following immunotherapy preceding thoracic radiotherapy (ICI-TRT) and establish safe dose constraints.Patients and Methods: This retrospective study enrolled patients diagnosed with non-small-cell lung cancer (NSCLC) who underwent thoracic radiotherapy (TRT) following immune checkpoint inhibitors (ICIs) treatment. The primary endpoint was the occurrence of symptomatic RP (Grade ≥ 2), as defined by the Common Terminology Criteria for Adverse Events version 5.0. Clinical and lung dosimetric parameters were analyzed to determine their associations with symptomatic RP. Dosimetric parameters included mean lung dose (MLD) and the percentage of lung volume receiving ≥ 10 Gy (V10), ≥ 20 Gy (V20), ≥ 30 Gy (V30), and ≥ 40 Gy (V40). Receiver operating characteristic curves were used to predict the risk of developing symptomatic RP to establish optimal threshold values for each dosimetric predictor.Results: Among the 118 patients included, the incidence of symptomatic RP was 25.4%. Tumor locations, intervals between immunotherapy and radiotherapy, and MLD, V10, V20, V30, and V40 were identified as independent risk factors for symptomatic RP. The area under the curve (AUC) values for MLD, V10, V20, V30, and V40 were 0.788 (95% confidence interval [CI] 0.704– 0.873), 0.789 (95% CI 0.705– 0.874), 0.791 (95% CI 0.706– 0.876), 0.784 (95% CI 0.697– 0.871), and 0.749 (95% CI 0.656– 0.842), respectively. The optimal threshold values for MLD, V10, V20, V30, and V40 were 9.7 Gy, 26.3%, 15.9%, 13.3%, and 8.6%, respectively. These thresholds are lower than current guideline recommendations, and maintaining dosimetric parameters below these values resulted in a cumulative symptomatic RP incidence of < 12%.Conclusion: The recommended dose thresholds for MLD, V10, V20, V30, and V40 are lower than the current guidelines, underscoring the importance of radiotherapy planning to minimize symptomatic RP occurrence in patients receiving ICI-TRT.Keywords: radiation therapy, immunotherapy, non-small-cell lung cancer, radiation pneumonitis, risk factors

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
Primary Topic
Cancer Immunotherapy and Biomarkers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dose-Volume Constraints Parameters for Lung Tissue in Thoracic Radiotherapy Following Immune Checkpoint Inhibitor Treatment

SHILAP Revista de lepidopterología
Cancer Immunotherapy and Biomarkers
article

Dose-Volume Constraints Parameters for Lung Tissue in Thoracic Radiotherapy Following Immune Checkpoint Inhibitor Treatment

article en

Abstract

Kang Wang,1 Fengchang Yang,1 Changxing Feng,1 Fuhao Xu,1 Li Li,1 Jinghao Duan,1 Shuanghu Yuan1,2 1Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, Shandong, People’s Republic of China; 2Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, People’s Republic of ChinaCorrespondence: Shuanghu Yuan, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No. 440 Jiyan Road, Jinan, Shandong, 250117, People’s Republic of China, Tel +86-531-67626931, Fax +86-531-87984079, Email [email protected]: This study aims to identify risk factors associated with symptomatic radiation pneumonitis (RP, Grade ≥ 2) following immunotherapy preceding thoracic radiotherapy (ICI-TRT) and establish safe dose constraints.Patients and Methods: This retrospective study enrolled patients diagnosed with non-small-cell lung cancer (NSCLC) who underwent thoracic radiotherapy (TRT) following immune checkpoint inhibitors (ICIs) treatment. The primary endpoint was the occurrence of symptomatic RP (Grade ≥ 2), as defined by the Common Terminology Criteria for Adverse Events version 5.0. Clinical and lung dosimetric parameters were analyzed to determine their associations with symptomatic RP. Dosimetric parameters included mean lung dose (MLD) and the percentage of lung volume receiving ≥ 10 Gy (V10), ≥ 20 Gy (V20), ≥ 30 Gy (V30), and ≥ 40 Gy (V40). Receiver operating characteristic curves were used to predict the risk of developing symptomatic RP to establish optimal threshold values for each dosimetric predictor.Results: Among the 118 patients included, the incidence of symptomatic RP was 25.4%. Tumor locations, intervals between immunotherapy and radiotherapy, and MLD, V10, V20, V30, and V40 were identified as independent risk factors for symptomatic RP. The area under the curve (AUC) values for MLD, V10, V20, V30, and V40 were 0.788 (95% confidence interval [CI] 0.704– 0.873), 0.789 (95% CI 0.705– 0.874), 0.791 (95% CI 0.706– 0.876), 0.784 (95% CI 0.697– 0.871), and 0.749 (95% CI 0.656– 0.842), respectively. The optimal threshold values for MLD, V10, V20, V30, and V40 were 9.7 Gy, 26.3%, 15.9%, 13.3%, and 8.6%, respectively. These thresholds are lower than current guideline recommendations, and maintaining dosimetric parameters below these values resulted in a cumulative symptomatic RP incidence of < 12%.Conclusion: The recommended dose thresholds for MLD, V10, V20, V30, and V40 are lower than the current guidelines, underscoring the importance of radiotherapy planning to minimize symptomatic RP occurrence in patients receiving ICI-TRT.Keywords: radiation therapy, immunotherapy, non-small-cell lung cancer, radiation pneumonitis, risk factors

SHILAP Revista de lepidopterología
Partnerships for the goals
Openalex Percentile: Top 45%
Cancer Immunotherapy and Biomarkers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.