Detection of Faulty Energizations in High Voltage Direct Current Power Cables by Analyzing Leakage Currents

The use of multi-terminal high voltage direct current (HVDC) power transmission systems is being adopted in many new links between different generation and consumption areas due to their high efficiency. In these systems, cable energization must be performed at the rated voltage. Healthy energizations at the rated voltage result in large inrush currents, especially in long cables, primarily due to ground capacitance. State-of-the-art protection functions struggle to distinguish between transients caused by switching and those associated with ground faults, leading to potential unwanted tripping of the protection systems. To prevent this, tripping is usually blocked during the energization transient, which delays fault detection and clearing. This paper presents a novel method for prompt discrimination between healthy and faulty energizations. The proposed method outperforms conventional protection functions as this discrimination allows for earlier and more reliable tripping, thus avoiding extensive damage to the cable and the converter due to trip blocking. The method is based on the transient analysis of the current in the cable shields, therefore, another technical advantage is that high voltage-insulated measuring devices are not required. Two distinct tripping criteria are proposed: one attending to the change in current polarity, and the other to the change in current derivative sign. Extensive computer simulations and laboratory tests confirmed the correct operation in both cases.

Publication Details

Journal
UPM Digital Archive (Technical University of Madrid)
Published
2024-10-19
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Faulty Energizations in High Voltage Direct Current Power Cables by Analyzing Leakage Currents

UPM Digital Archive (Technical University of Madrid)
Electrical Fault Detection and Protection
article

Detection of Faulty Energizations in High Voltage Direct Current Power Cables by Analyzing Leakage Currents

article en

Abstract

The use of multi-terminal high voltage direct current (HVDC) power transmission systems is being adopted in many new links between different generation and consumption areas due to their high efficiency. In these systems, cable energization must be performed at the rated voltage. Healthy energizations at the rated voltage result in large inrush currents, especially in long cables, primarily due to ground capacitance. State-of-the-art protection functions struggle to distinguish between transients caused by switching and those associated with ground faults, leading to potential unwanted tripping of the protection systems. To prevent this, tripping is usually blocked during the energization transient, which delays fault detection and clearing. This paper presents a novel method for prompt discrimination between healthy and faulty energizations. The proposed method outperforms conventional protection functions as this discrimination allows for earlier and more reliable tripping, thus avoiding extensive damage to the cable and the converter due to trip blocking. The method is based on the transient analysis of the current in the cable shields, therefore, another technical advantage is that high voltage-insulated measuring devices are not required. Two distinct tripping criteria are proposed: one attending to the change in current polarity, and the other to the change in current derivative sign. Extensive computer simulations and laboratory tests confirmed the correct operation in both cases.

UPM Digital Archive (Technical University of Madrid)
Peace, Justice and strong institutions
Openalex Percentile: Top 64%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of Faulty Energizations in High Voltage Direct Current Power Cables by Analyzing Leakage Currents · UPM Digital Archive (Technical University of Madrid) (2024) | TGRS Research Map | TGRS