A comparison between a new foot-mounted inertial measurement system and a local positioning system in amateur futsal

This study aimed to 1) establish the level of agreement between a foot-mounted inertial measurement system (PlayerMaker™) and a local positioning system (Catapult ClearSky™) for time-motion analysis variables in recreational futsal, (2) determine the level of agreement between the technical futsal performance variables of the foot-mounted inertial measurement units and video analysis (Catapult Vision), and 3) assess the match-to-match variability of the futsal players’ physical and technical performances throughout recreational games of futsal. Twenty-eight male participants (mean ± SD age: 32.8 ± 11.7 years; stature: 179.6 ± 8.8 cm; mass: 83.4 ± 12.2 kg), each wearing a pair of PlayerMaker™ sensors and a Catapult ClearSky™ S7 Vector unit, played ten-minute games of five a side recreational futsal across the data collection period. The level of agreement for total distance covered (meters) between the PlayerMaker™ sensors (790 ± 107) and Catapult ClearSky™ (780 ± 104) was measured. The maximum velocity (meters per second) metric was quantified PlayerMaker™ (5.3 ± 0.6) and Catapult ClearSky™ (5.3 ± 0.7) to represent the level of agreement between the two systems. The level of agreement for the number of ball releases per futsal game was analysed in the present study between PlayerMaker™ (8.1 ± 5.9) and video analysis (16.1 ± 5.1). The level of agreement between PlayerMaker™ (18.5 ± 6.5) and video analysis (37.3 ± 5.3) for the number of ball touches per futsal game was also analysed. This study recommends the PlayerMaker™ inertial measurement system is utilised as a cheaper alternative to an LPS for quantifying time-motion analysis variables indoors. The PlayerMaker™ sensors might serve as a valid and reliable alternative to an LPS, but sporting practitioners must remain aware of the shortcomings of the system or of the various factors that compromise the quality of data produced by it.

Publication Details

Journal
Repository@Hull (Worktribe) (University of Hull)
Published
2025-02-27
Primary Topic
Sports injuries and prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparison between a new foot-mounted inertial measurement system and a local positioning system in amateur futsal

Repository@Hull (Worktribe) (University of Hull)
Sports injuries and prevention
article

A comparison between a new foot-mounted inertial measurement system and a local positioning system in amateur futsal

article en

Abstract

This study aimed to 1) establish the level of agreement between a foot-mounted inertial measurement system (PlayerMaker™) and a local positioning system (Catapult ClearSky™) for time-motion analysis variables in recreational futsal, (2) determine the level of agreement between the technical futsal performance variables of the foot-mounted inertial measurement units and video analysis (Catapult Vision), and 3) assess the match-to-match variability of the futsal players’ physical and technical performances throughout recreational games of futsal. Twenty-eight male participants (mean ± SD age: 32.8 ± 11.7 years; stature: 179.6 ± 8.8 cm; mass: 83.4 ± 12.2 kg), each wearing a pair of PlayerMaker™ sensors and a Catapult ClearSky™ S7 Vector unit, played ten-minute games of five a side recreational futsal across the data collection period. The level of agreement for total distance covered (meters) between the PlayerMaker™ sensors (790 ± 107) and Catapult ClearSky™ (780 ± 104) was measured. The maximum velocity (meters per second) metric was quantified PlayerMaker™ (5.3 ± 0.6) and Catapult ClearSky™ (5.3 ± 0.7) to represent the level of agreement between the two systems. The level of agreement for the number of ball releases per futsal game was analysed in the present study between PlayerMaker™ (8.1 ± 5.9) and video analysis (16.1 ± 5.1). The level of agreement between PlayerMaker™ (18.5 ± 6.5) and video analysis (37.3 ± 5.3) for the number of ball touches per futsal game was also analysed. This study recommends the PlayerMaker™ inertial measurement system is utilised as a cheaper alternative to an LPS for quantifying time-motion analysis variables indoors. The PlayerMaker™ sensors might serve as a valid and reliable alternative to an LPS, but sporting practitioners must remain aware of the shortcomings of the system or of the various factors that compromise the quality of data produced by it.

Repository@Hull (Worktribe) (University of Hull)
Openalex Percentile: Top 42%
Sports injuries and prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.