Comparison of Self-Test Refraction, Autorefraction, and Subjective Refraction

Abraão Ferreira de Sousa Neto Kós,1 Bernardo Kaplan Moscovici,2,3 Cesar Vilar,1 Mario Augusto Pereira Dias Chaves,4 Maíra Gomes Barbosa Da Silva,1 Maurício Agne Neuwald,1 André Lins De Medeiros,1 Jonathan Clive Lake,1 Antonio Francisco Pimenta Motta,5 Patrick Frensel de Moraes Tzelikis,1 Pedro Carlos Carricondo,6 Larissa Gouvea,7 Walton Nosé,2 Wilson Takashi Hida1,4 1Hospital Oftalmologico de Brasília - HOB, Brasilia, Brasilia, Brazil; 2Department of Ophthalmology and Visual Sciences, Federal University of Sao Paulo UNIFESP, São Paulo, Brazil; 3Department of Ophthalmology, Hospital Visão Laser, Santos, Brazil; 4Department of Ophthalmology, Hospital Oftalmologico da Paraiba, Paraiba, Brazil; 5Department of Ophthalmology, Renato Ambrosio Research Center CEORA, Rio de Janeiro, Brazil; 6Department of Ophthalmology, University of Sao Paulo HC-FM USP, São Paulo, Brazil; 7Storm Eye Institute, Medical University of South Carolina, Charleston, SC, USACorrespondence: Bernardo Kaplan Moscovici, Email [email protected]: To compare the performance of a self-refraction device (EyeQue Vision Check 2, EyeQue, USA) with autorefraction (OPD-Scan III, NIDEK) and subjective cycloplegic refraction in measuring refractive errors.Methods: This descriptive study included 80 eyes from 40 patients. Measurements were obtained using the portable EyeQue device, OPD-Scan III, and subjective cycloplegic refraction performed by an experienced examiner. Spherical equivalent (SE), cylindrical power, and axis values were analyzed using power vector decomposition (M, J0, J45) to improve accuracy in comparing methods. The main outcome was the agreement between self-refraction, autorefraction, and subjective refraction.Results: The EyeQue device showed lower variability and greater homogeneity in spherical measurements but exhibited lower precision for cylindrical power and axis than subjective refraction. Power vector analysis revealed that EyeQue overestimated spherical equivalent (M) and produced higher J0 values, suggesting a tendency to alter cylindrical correction. Although comparable to OPD-Scan in spherical refraction, EyeQue demonstrated inconsistencies in astigmatism correction, particularly in J45 components.Conclusion: The EyeQue device is a promising tool for large-scale screenings due to its affordability and portability. However, its limitations in astigmatism and axis measurements indicate that subjective refraction should complement rather than replace it. Therefore, further refinement and validation in diverse populations are recommended.Keywords: self-refraction, autorefraction, subjective refraction, power vector analysis, teleophthalmology

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Self-Test Refraction, Autorefraction, and Subjective Refraction

SHILAP Revista de lepidopterología
Ophthalmology and Visual Impairment Studies
article

Comparison of Self-Test Refraction, Autorefraction, and Subjective Refraction

article en

Abstract

Abraão Ferreira de Sousa Neto Kós,1 Bernardo Kaplan Moscovici,2,3 Cesar Vilar,1 Mario Augusto Pereira Dias Chaves,4 Maíra Gomes Barbosa Da Silva,1 Maurício Agne Neuwald,1 André Lins De Medeiros,1 Jonathan Clive Lake,1 Antonio Francisco Pimenta Motta,5 Patrick Frensel de Moraes Tzelikis,1 Pedro Carlos Carricondo,6 Larissa Gouvea,7 Walton Nosé,2 Wilson Takashi Hida1,4 1Hospital Oftalmologico de Brasília - HOB, Brasilia, Brasilia, Brazil; 2Department of Ophthalmology and Visual Sciences, Federal University of Sao Paulo UNIFESP, São Paulo, Brazil; 3Department of Ophthalmology, Hospital Visão Laser, Santos, Brazil; 4Department of Ophthalmology, Hospital Oftalmologico da Paraiba, Paraiba, Brazil; 5Department of Ophthalmology, Renato Ambrosio Research Center CEORA, Rio de Janeiro, Brazil; 6Department of Ophthalmology, University of Sao Paulo HC-FM USP, São Paulo, Brazil; 7Storm Eye Institute, Medical University of South Carolina, Charleston, SC, USACorrespondence: Bernardo Kaplan Moscovici, Email [email protected]: To compare the performance of a self-refraction device (EyeQue Vision Check 2, EyeQue, USA) with autorefraction (OPD-Scan III, NIDEK) and subjective cycloplegic refraction in measuring refractive errors.Methods: This descriptive study included 80 eyes from 40 patients. Measurements were obtained using the portable EyeQue device, OPD-Scan III, and subjective cycloplegic refraction performed by an experienced examiner. Spherical equivalent (SE), cylindrical power, and axis values were analyzed using power vector decomposition (M, J0, J45) to improve accuracy in comparing methods. The main outcome was the agreement between self-refraction, autorefraction, and subjective refraction.Results: The EyeQue device showed lower variability and greater homogeneity in spherical measurements but exhibited lower precision for cylindrical power and axis than subjective refraction. Power vector analysis revealed that EyeQue overestimated spherical equivalent (M) and produced higher J0 values, suggesting a tendency to alter cylindrical correction. Although comparable to OPD-Scan in spherical refraction, EyeQue demonstrated inconsistencies in astigmatism correction, particularly in J45 components.Conclusion: The EyeQue device is a promising tool for large-scale screenings due to its affordability and portability. However, its limitations in astigmatism and axis measurements indicate that subjective refraction should complement rather than replace it. Therefore, further refinement and validation in diverse populations are recommended.Keywords: self-refraction, autorefraction, subjective refraction, power vector analysis, teleophthalmology

SHILAP Revista de lepidopterología
Openalex Percentile: Top 39%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.