The Relevance of the Technical Error of Measurement in Anthropometry: A Pilot Study from The Nutrifunction Project

Introduction. Anthropometry plays a crucial role in nutritional assessment, especially in clinical and research settings where lack of precision affects data reliability and patient care. However, the accuracy of these measurements is often overlooked when assessing nutritional status and health risks. This study aimed to assess the technical error of measurement (TEM) and evaluate the intra- and inter-observer measurement error of anthropometric measurements performed by the NutriFunction team—an ongoing multicentre study involving hospitalised patients and a comparative sample of community-dwelling individuals. Methods. Six trained interviewers assessed twelve anthropometric indicators (body weight, body and knee height, hand and middle-finger lengths, hand breadth, mid-arm, waist, and calf circumferences, triceps, calf, and adductor pollicis thickness) on eight volunteers following ISAK and other pre-standardized techniques. TEM, relative TEM (%TEM), and coefficient of reliability (R) were calculated. Results. Most results were adequate for experienced anthropometrists, except for hand breadth (%TEM=1.2) and knee height (%TEM=1.2) for anthropometrist #4, and middle-finger length (%TEM=1.3) for #5 in intra-observer variability (R range=0.6-1.0). Inter-observer variability showed unacceptable %TEM for hand length (%TEM=2.0, 2.5, 1.5) for anthropometrists #1, #2, and #5, hand breadth (%TEM=2.0) for #4, adductor pollicis thickness (%TEM=9.9, 14.5) for #1 and #2, and middle-finger length (%TEM=2.0) for #5 (R range: 0.3-1.0). For the beginner standard, intra-observer variability was acceptable across all points, but inter-observer variability was unacceptable for hand length (%TEM=2.5) and adductor pollicis thickness (%TEM=14.5) for anthropometrist #2. Conclusions. Most anthropometric measurements had acceptable TEM values for experienced anthropometrists, meaning that these measurements present the necessary precision for clinical assessment and diagnosis. Anthropometrist #2 should not perform hand length and adductor pollicis thickness measurements until further training and a new TEM study are completed. Regular training is essential to minimise errors and safeguard the quality and clinical utility of anthropometric data for assessment, diagnosis and treatment. Funding: Fellowship FCT (2023.01790.BD). and European Regional Development Fund (NORTE-01-0145-FEDER-000039).

Publication Details

Journal
Dialnet (Universidad de la Rioja)
Published
2025-01-01
Primary Topic
Marine Invertebrate Physiology and Ecology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Relevance of the Technical Error of Measurement in Anthropometry: A Pilot Study from The Nutrifunction Project

Dialnet (Universidad de la Rioja)
Marine Invertebrate Physiology and Ecology
article

The Relevance of the Technical Error of Measurement in Anthropometry: A Pilot Study from The Nutrifunction Project

article en

Abstract

Introduction. Anthropometry plays a crucial role in nutritional assessment, especially in clinical and research settings where lack of precision affects data reliability and patient care. However, the accuracy of these measurements is often overlooked when assessing nutritional status and health risks. This study aimed to assess the technical error of measurement (TEM) and evaluate the intra- and inter-observer measurement error of anthropometric measurements performed by the NutriFunction team—an ongoing multicentre study involving hospitalised patients and a comparative sample of community-dwelling individuals. Methods. Six trained interviewers assessed twelve anthropometric indicators (body weight, body and knee height, hand and middle-finger lengths, hand breadth, mid-arm, waist, and calf circumferences, triceps, calf, and adductor pollicis thickness) on eight volunteers following ISAK and other pre-standardized techniques. TEM, relative TEM (%TEM), and coefficient of reliability (R) were calculated. Results. Most results were adequate for experienced anthropometrists, except for hand breadth (%TEM=1.2) and knee height (%TEM=1.2) for anthropometrist #4, and middle-finger length (%TEM=1.3) for #5 in intra-observer variability (R range=0.6-1.0). Inter-observer variability showed unacceptable %TEM for hand length (%TEM=2.0, 2.5, 1.5) for anthropometrists #1, #2, and #5, hand breadth (%TEM=2.0) for #4, adductor pollicis thickness (%TEM=9.9, 14.5) for #1 and #2, and middle-finger length (%TEM=2.0) for #5 (R range: 0.3-1.0). For the beginner standard, intra-observer variability was acceptable across all points, but inter-observer variability was unacceptable for hand length (%TEM=2.5) and adductor pollicis thickness (%TEM=14.5) for anthropometrist #2. Conclusions. Most anthropometric measurements had acceptable TEM values for experienced anthropometrists, meaning that these measurements present the necessary precision for clinical assessment and diagnosis. Anthropometrist #2 should not perform hand length and adductor pollicis thickness measurements until further training and a new TEM study are completed. Regular training is essential to minimise errors and safeguard the quality and clinical utility of anthropometric data for assessment, diagnosis and treatment. Funding: Fellowship FCT (2023.01790.BD). and European Regional Development Fund (NORTE-01-0145-FEDER-000039).

Dialnet (Universidad de la Rioja)
Fundação para a Ciência e a Tecnologia, European Regional Development Fund
Zero hunger
Openalex Percentile: Top 43%
Marine Invertebrate Physiology and Ecology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Relevance of the Technical Error of Measurement in Anthropometry: A Pilot Study from The Nutrifunction Project · Dialnet (Universidad de la Rioja) (2025) | TGRS Research Map | TGRS