Efficient dual loop PFC for challenging dynamic processes

When controlling difficult industrial processes characterised by open-loop instability and/or poor damping, predictive functional control (PFC) practitioners often face two critical design challenges. The first one arises due to the intrinsic simplicity of the PFC control algorithm that, instead of optimising the future control trajectory in real time like other predictive controllers, simply assumes constant control action, thereby producing unreliable model predictions in the long range and thus inconsistent closed-loop performance. The second issue is related to the controller tuning, which may become ambiguous and unsystematic due to the existence of an inconsistent relationship between the controller parameters and closed-loop behaviour. This paper presents a dual-loop control strategy that aims at mitigating both weaknesses simultaneously by combining the concepts of pre-stabilisation and relative tuning within the framework of predictive functional control. Two challenging industrial case studies have been analysed through computer simulations that successfully validate the efficacy of the proposal under various real world scenarios.

Publication Details

Journal
White Rose Research Online (University of Leeds, The University of Sheffield, University of York)
Published
2025-03-14
Primary Topic
Advanced Control Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient dual loop PFC for challenging dynamic processes

White Rose Research Online (University of Leeds, The University of Sheffield, University of York)
Advanced Control Systems Optimization
article

Efficient dual loop PFC for challenging dynamic processes

article en

Abstract

When controlling difficult industrial processes characterised by open-loop instability and/or poor damping, predictive functional control (PFC) practitioners often face two critical design challenges. The first one arises due to the intrinsic simplicity of the PFC control algorithm that, instead of optimising the future control trajectory in real time like other predictive controllers, simply assumes constant control action, thereby producing unreliable model predictions in the long range and thus inconsistent closed-loop performance. The second issue is related to the controller tuning, which may become ambiguous and unsystematic due to the existence of an inconsistent relationship between the controller parameters and closed-loop behaviour. This paper presents a dual-loop control strategy that aims at mitigating both weaknesses simultaneously by combining the concepts of pre-stabilisation and relative tuning within the framework of predictive functional control. Two challenging industrial case studies have been analysed through computer simulations that successfully validate the efficacy of the proposal under various real world scenarios.

White Rose Research Online (University of Leeds, The University of Sheffield, University of York)
No poverty
Openalex Percentile: Top 45%
Advanced Control Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Efficient dual loop PFC for challenging dynamic processes · White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (2025) | TGRS Research Map | TGRS