Design and validation of ultrasound-guided femoral vein puncture robots

ObjectiveFemoral veni puncture is widely used in clinical scenarios such as critical emergency treatment, emergency dialysis, drug rehydration, etc. However, the success rate of femoral veni puncture often depends on the experience of doctors. Thus, an ultrasound-guided robot system for femoral vein puncture was developed.MethodsFirstly, a 2-DOF end puncture actuator of the puncture robot was designed for angle adjustment of the swing arm and femoral vein puncture feeding.Then, based on the 7-DOF serial robot arm, an ultrasound-guided femoral vein puncture robot system was built to ensure the space of ultrasound scanning and puncture. Finally, the positioning accuracy of the end puncture actuator and the robot was verified.ResultsThe test results show that the absolute positioning accuracy of the angle of the puncture swing arm of the end puncture actuator is within 0.5°, the absolute positioning accuracy of the puncture feed is within 0.2 mm, and the spatial repeated positioning accuracy of the needle tip of the femoral vein puncture robot based on the 7-DOF robot arm is within 0.2 mm, meeting the requirements of clinical puncture accuracy. The robot system is built to realize semi-automatic puncture through remote operation, which provides important experience for realizing automatic puncture of femoral veins.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and validation of ultrasound-guided femoral vein puncture robots

SHILAP Revista de lepidopterología
Soft Robotics and Applications
article

Design and validation of ultrasound-guided femoral vein puncture robots

article en

Abstract

ObjectiveFemoral veni puncture is widely used in clinical scenarios such as critical emergency treatment, emergency dialysis, drug rehydration, etc. However, the success rate of femoral veni puncture often depends on the experience of doctors. Thus, an ultrasound-guided robot system for femoral vein puncture was developed.MethodsFirstly, a 2-DOF end puncture actuator of the puncture robot was designed for angle adjustment of the swing arm and femoral vein puncture feeding.Then, based on the 7-DOF serial robot arm, an ultrasound-guided femoral vein puncture robot system was built to ensure the space of ultrasound scanning and puncture. Finally, the positioning accuracy of the end puncture actuator and the robot was verified.ResultsThe test results show that the absolute positioning accuracy of the angle of the puncture swing arm of the end puncture actuator is within 0.5°, the absolute positioning accuracy of the puncture feed is within 0.2 mm, and the spatial repeated positioning accuracy of the needle tip of the femoral vein puncture robot based on the 7-DOF robot arm is within 0.2 mm, meeting the requirements of clinical puncture accuracy. The robot system is built to realize semi-automatic puncture through remote operation, which provides important experience for realizing automatic puncture of femoral veins.

SHILAP Revista de lepidopterología
Good health and well-being
Openalex Percentile: Top 53%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.