Development and Validation of a CTE-Based Radiomics Nomogram for Predicting Clinical Adverse Outcomes in Patients with Stricturing Crohn’s Disease

Bo Zhang,1,* Yankun Gao,1,* Li Tong,2 Jing Hu,3 Xingwang Wu1 1Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230022, People’s Republic of China; 2Department of Radiology, The Third Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230061, People’s Republic of China; 3Department of Gastroenterology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230022, People’s Republic of China*These authors contributed equally to this workCorrespondence: Xingwang Wu, Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230022, People’s Republic of China, Email [email protected]: This study sought to develop and validate a radiomics nomogram using computed tomography enterography (CTE) to predict clinical adverse outcomes (CAO) in patients with stricturing Crohn’s disease (CD), aiding in personalized treatment planning.Methods: We retrospectively collected data from 219 patients diagnosed with stricturing CD between January 2018 and March 2023 at our institution, dividing them into a training set (n=153) and a testing set (n=66). Radiomics features from strictured segments were extracted and the most predictive features were identified using Pearson correlation, SelectKBest, and Least Absolute Shrinkage and Selection Operator (LASSO) regression to derive a Radiomics score (Rad-score). Cox regression was used to select key clinical predictors of CAO. A radiomics nomogram was developed to predict CAO, evaluated using Harrell’s concordance index (C-index), time-dependent Receiver Operating Characteristic (ROC) curves, and Decision Curve Analysis (DCA).Results: Univariate and multivariate Cox regression analyses of the training set identified the HBI score (HR=0.443, 95% CI=0.212– 0.925, P=0.030) and the diameter of the upstream lumen (HR=1.080, 95% CI=1.050– 1.111, P< 0.001) as independent clinical predictors of CAO in stricturing CD. Nineteen features related to CAO outcomes were selected for Rad-score calculation. In the testing set, the C-index for the clinical, radiomics, and nomogram models were 0.752, 0.775, and 0.849, respectively. The AUCs of the nomogram model at 1, 2, and 3 years were 0.874, 0.863, and 0.956, respectively.Conclusion: The CTE-based radiomics nomogram significantly outperformed clinical and radiomics models alone and demonstrated excellent predictive accuracy for CAO risk. By integrating the HBI score and upstream lumen diameter with radiomics features, this tool provides clinicians with a validated, noninvasive method to stratify stricturing CD patients by risk and guide personalized therapeutic decisions.Keywords: radiomics, computed tomography enterography, Crohn’s disease, outcomes

Publication Details

Journal
Dove Medical Press (Taylor and Francis Group)
Published
2025-08-08
Primary Topic
Inflammatory Bowel Disease
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a CTE-Based Radiomics Nomogram for Predicting Clinical Adverse Outcomes in Patients with Stricturing Crohn’s Disease

Dove Medical Press (Taylor and Francis Group)
Inflammatory Bowel Disease
article

Development and Validation of a CTE-Based Radiomics Nomogram for Predicting Clinical Adverse Outcomes in Patients with Stricturing Crohn’s Disease

article en

Abstract

Bo Zhang,1,* Yankun Gao,1,* Li Tong,2 Jing Hu,3 Xingwang Wu1 1Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230022, People’s Republic of China; 2Department of Radiology, The Third Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230061, People’s Republic of China; 3Department of Gastroenterology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230022, People’s Republic of China*These authors contributed equally to this workCorrespondence: Xingwang Wu, Department of Radiology, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, 230022, People’s Republic of China, Email [email protected]: This study sought to develop and validate a radiomics nomogram using computed tomography enterography (CTE) to predict clinical adverse outcomes (CAO) in patients with stricturing Crohn’s disease (CD), aiding in personalized treatment planning.Methods: We retrospectively collected data from 219 patients diagnosed with stricturing CD between January 2018 and March 2023 at our institution, dividing them into a training set (n=153) and a testing set (n=66). Radiomics features from strictured segments were extracted and the most predictive features were identified using Pearson correlation, SelectKBest, and Least Absolute Shrinkage and Selection Operator (LASSO) regression to derive a Radiomics score (Rad-score). Cox regression was used to select key clinical predictors of CAO. A radiomics nomogram was developed to predict CAO, evaluated using Harrell’s concordance index (C-index), time-dependent Receiver Operating Characteristic (ROC) curves, and Decision Curve Analysis (DCA).Results: Univariate and multivariate Cox regression analyses of the training set identified the HBI score (HR=0.443, 95% CI=0.212– 0.925, P=0.030) and the diameter of the upstream lumen (HR=1.080, 95% CI=1.050– 1.111, P< 0.001) as independent clinical predictors of CAO in stricturing CD. Nineteen features related to CAO outcomes were selected for Rad-score calculation. In the testing set, the C-index for the clinical, radiomics, and nomogram models were 0.752, 0.775, and 0.849, respectively. The AUCs of the nomogram model at 1, 2, and 3 years were 0.874, 0.863, and 0.956, respectively.Conclusion: The CTE-based radiomics nomogram significantly outperformed clinical and radiomics models alone and demonstrated excellent predictive accuracy for CAO risk. By integrating the HBI score and upstream lumen diameter with radiomics features, this tool provides clinicians with a validated, noninvasive method to stratify stricturing CD patients by risk and guide personalized therapeutic decisions.Keywords: radiomics, computed tomography enterography, Crohn’s disease, outcomes

Dove Medical Press (Taylor and Francis Group)
Peace, Justice and strong institutions
Openalex Percentile: Top 40%
Inflammatory Bowel Disease
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.