All-solid-state Lead(II)–Selective Potentiometric Sensor Based on 9,10-dibromo-2-(propylthio)anthracene-1,4-dione

Ion-selective sensors are widely used in routine analysis of ionic species. In this research, a highly selective potentiometric sensor was developed, which is sensitive against Pb2+ ions compared to other common inorganic cations. The optimum composition of the developed sensor was determined to be as 3.0% ionophore, 64.0% bis(2–ethylhexyl)adipate (DEHA), 32.0% poly (vinyl chloride) (PVC), and 1.0% anion excluder (KTpClPB). The Pb2+–selective sensor had a Nernstian response of 28.7±2.2 mV/decade over a wide linear range of 1.0×10-5–1.0×10-1 M and a low detection limit of 2.77×10-6 M. The newly developed sensor worked over a wide pH range (4.0–10.0), and the response time was short (7s). The sensor, which had good reproducibility, was applied to various water samples and determined Pb2+ ions with very high recoveries.

Institutions

Publication Details

Journal
DergiPark (Istanbul University)
Published
2025-01-22
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

All-solid-state Lead(II)–Selective Potentiometric Sensor Based on 9,10-dibromo-2-(propylthio)anthracene-1,4-dione

DergiPark (Istanbul University)
Analytical Chemistry and Sensors
article

All-solid-state Lead(II)–Selective Potentiometric Sensor Based on 9,10-dibromo-2-(propylthio)anthracene-1,4-dione

article en

Abstract

Ion-selective sensors are widely used in routine analysis of ionic species. In this research, a highly selective potentiometric sensor was developed, which is sensitive against Pb2+ ions compared to other common inorganic cations. The optimum composition of the developed sensor was determined to be as 3.0% ionophore, 64.0% bis(2–ethylhexyl)adipate (DEHA), 32.0% poly (vinyl chloride) (PVC), and 1.0% anion excluder (KTpClPB). The Pb2+–selective sensor had a Nernstian response of 28.7±2.2 mV/decade over a wide linear range of 1.0×10-5–1.0×10-1 M and a low detection limit of 2.77×10-6 M. The newly developed sensor worked over a wide pH range (4.0–10.0), and the response time was short (7s). The sensor, which had good reproducibility, was applied to various water samples and determined Pb2+ ions with very high recoveries.

DergiPark (Istanbul University)
Tokat Gaziosmanpaşa Üniversitesi (TR)
Life below water
Openalex Percentile: Top 50%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.