Surface Characterization of Porous Ti-6Al-4V Dental Implant by Metal Injection Molding with Palm Stearin Binder System

The osseointegration rate of Ti-6Al-4V dental implants is related to their composition and surface roughness. Rough-surfaced implants favour both bone anchoring and biochemical stability. This paper focused on the surface characteristic of highly porous Ti-6Al-4V dental implant by metal injection molding with palm stearin binder system with an addition of sodium chloride as space holder which has been established in the fabrication of porous Ti-6Al-4V. The integrated pores obtained on the dental implant provides the space for mineralized bone to growth and diffuse into the dental implant and improve the anchorage of the dental implant towards the bone and prevent dental implant loosening. The average surface roughness (Ra) of 4.62 ± 1.33 µm and 5.83 ± 1.25 µm was within the proposed ideal surface roughness of 1-10µm. In addition, the existence of lamellar of α-β phase on the surface as-polished dental implant would improve both the mechanical as well as the elastic properties.

Publication Details

Journal
International Journal of Sustainable Construction Engineering and Technology (Universiti Tun Hussein Onn Malaysia)
Published
2024-12-30
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surface Characterization of Porous Ti-6Al-4V Dental Implant by Metal Injection Molding with Palm Stearin Binder System

International Journal of Sustainable Construction Engineering and Technology (Universiti Tun Hussein Onn Malaysia)
Bone Tissue Engineering Materials
article

Surface Characterization of Porous Ti-6Al-4V Dental Implant by Metal Injection Molding with Palm Stearin Binder System

article en

Abstract

The osseointegration rate of Ti-6Al-4V dental implants is related to their composition and surface roughness. Rough-surfaced implants favour both bone anchoring and biochemical stability. This paper focused on the surface characteristic of highly porous Ti-6Al-4V dental implant by metal injection molding with palm stearin binder system with an addition of sodium chloride as space holder which has been established in the fabrication of porous Ti-6Al-4V. The integrated pores obtained on the dental implant provides the space for mineralized bone to growth and diffuse into the dental implant and improve the anchorage of the dental implant towards the bone and prevent dental implant loosening. The average surface roughness (Ra) of 4.62 ± 1.33 µm and 5.83 ± 1.25 µm was within the proposed ideal surface roughness of 1-10µm. In addition, the existence of lamellar of α-β phase on the surface as-polished dental implant would improve both the mechanical as well as the elastic properties.

International Journal of Sustainable Construction Engineering and Technology (Universiti Tun Hussein Onn Malaysia)
Openalex Percentile: Top 63%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Surface Characterization of Porous Ti-6Al-4V Dental Implant by Metal Injection Molding with Palm Stearin Binder System · International Journal of Sustainable Construction Engineering and Technology (Universiti Tun Hussein Onn Malaysia) (2024) | TGRS Research Map | TGRS