A Retrospective Study of Visual Outcomes When Using a Cloud-Based Surgical Planning Platform and the Barrett Universal II Formula

Eric Jennings,1 Brad Hall2 1Woolfson Eye Institute, Atlanta, GA, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Eric Jennings, Woolfson Eye Institute 800 Mount Vernon Hwy NE Suite 130, Atlanta, GA, 30501, USA, Tel +1-404-256-1125, Email [email protected]: To evaluate the efficacy of a cloud-based surgical planning platform with regards to refractive target accuracy.Methods: This was a retrospective chart review of consecutive cases from January 2022 through December 2023. Surgical planning was performed using the SMARTCataract platform, eyes were implanted with Clareon monofocal IOLs, and power calculations were done using the Barrett Universal II formula. Data were collected for the percentage of eyes within ± 0.5 D of target refraction, mean absolute error (MAE), and postoperative visual acuity.Results: A total of 148 eyes were identified that met the inclusion/exclusion criteria. The percentage of eyes within ± 0.5 D of the planned target was 94%. The MAE was 0.25 ± 0.17 D. In addition, 57%, 93%, 98%, and 100% of eyes had MAE ≤ 0.25 D, ≤ 0.5 D, ≤ 0.75 D, and ≤ 1.0 D, respectively.Conclusion: The results of this study suggest high refractive accuracy when using the SMARTCataract planning platform with the Barrett Universal II formula and excellent distance visual acuity.Plain Language Summary: When the natural lens inside the eye develops a cataract (becomes opaque) it can be replaced with a clear artificial intraocular lens (IOL). Good visual outcomes after surgery are heavily reliant on implanting the optimal lens power. A new cloud-based surgical planning tool (SMARTCataract) aims to automatically use patient data, surgeon preferences, favored IOL power calculation formulas, and desired IOL type to guide surgical planning. However, to date there are no data on the refractive outcomes when using the SMARTCataract platform. The purpose of this study was to evaluate the efficacy of the SMARTCataract platform with regards to refractive target accuracy. The results of this study suggest high refractive accuracy when using the SMARTCataract platform with the Barrett Universal II formula and excellent distance visual acuity.Keywords: SMARTCataract, biometry, accuracy, intraocular lens

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Retrospective Study of Visual Outcomes When Using a Cloud-Based Surgical Planning Platform and the Barrett Universal II Formula

SHILAP Revista de lepidopterología
Ophthalmology and Visual Impairment Studies
article

A Retrospective Study of Visual Outcomes When Using a Cloud-Based Surgical Planning Platform and the Barrett Universal II Formula

article en

Abstract

Eric Jennings,1 Brad Hall2 1Woolfson Eye Institute, Atlanta, GA, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Eric Jennings, Woolfson Eye Institute 800 Mount Vernon Hwy NE Suite 130, Atlanta, GA, 30501, USA, Tel +1-404-256-1125, Email [email protected]: To evaluate the efficacy of a cloud-based surgical planning platform with regards to refractive target accuracy.Methods: This was a retrospective chart review of consecutive cases from January 2022 through December 2023. Surgical planning was performed using the SMARTCataract platform, eyes were implanted with Clareon monofocal IOLs, and power calculations were done using the Barrett Universal II formula. Data were collected for the percentage of eyes within ± 0.5 D of target refraction, mean absolute error (MAE), and postoperative visual acuity.Results: A total of 148 eyes were identified that met the inclusion/exclusion criteria. The percentage of eyes within ± 0.5 D of the planned target was 94%. The MAE was 0.25 ± 0.17 D. In addition, 57%, 93%, 98%, and 100% of eyes had MAE ≤ 0.25 D, ≤ 0.5 D, ≤ 0.75 D, and ≤ 1.0 D, respectively.Conclusion: The results of this study suggest high refractive accuracy when using the SMARTCataract planning platform with the Barrett Universal II formula and excellent distance visual acuity.Plain Language Summary: When the natural lens inside the eye develops a cataract (becomes opaque) it can be replaced with a clear artificial intraocular lens (IOL). Good visual outcomes after surgery are heavily reliant on implanting the optimal lens power. A new cloud-based surgical planning tool (SMARTCataract) aims to automatically use patient data, surgeon preferences, favored IOL power calculation formulas, and desired IOL type to guide surgical planning. However, to date there are no data on the refractive outcomes when using the SMARTCataract platform. The purpose of this study was to evaluate the efficacy of the SMARTCataract platform with regards to refractive target accuracy. The results of this study suggest high refractive accuracy when using the SMARTCataract platform with the Barrett Universal II formula and excellent distance visual acuity.Keywords: SMARTCataract, biometry, accuracy, intraocular lens

SHILAP Revista de lepidopterología
Reduced inequalities
Openalex Percentile: Top 45%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Retrospective Study of Visual Outcomes When Using a Cloud-Based Surgical Planning Platform and the Barrett Universal II Formula · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS