Optimizing Infusate Flow Patterns for Minimizing Vein Wall Trauma: An Exploratory Study with a Modified off-Axis Catheter Tip Opening

Amit Bahl,1 S Matthew Gibson,2 Alexis Walton3 1Department of Emergency Medicine, Oakland University William Beaumont School of Medicine, Rochester, MI, USA; 2Vascular Access Consulting, Henderson, KY, USA; 3Department of Emergency Medicine, Corewell Health William Beaumont University Hospital, Royal Oak, MI, USACorrespondence: Amit Bahl, Oakland University William Beaumont School of Medicine, 586 Pioneer Drive, Rochester, MI, 48309, USA, Email [email protected]: Modifying the PIVC tip to direct infusates toward areas of highest hemodilution may reduce vein wall damage. This study compared flow patterns between a traditional PIVC with a central opening and one with an off-axis aperture.Methods: This was an exploratory observational analysis conducted at a tertiary care emergency department (ED) comparing flow patterns of two intravenous catheters: PIVC 1 (2.95 cm 20 gauge [Autoguard, Becton Dickinson]) and PIVC 2 (3.68 cm 20 gauge [Osprey, SkyDance Vascular]). Adult ED patients with PIVCs placed via traditional palpation/visualization method and with ultrasound capturing the flushing were eligible participants. Ultrasounds were reviewed to determine vein, catheter, and flow characteristics. The primary outcome was angle of the infusate leaving the catheter. Secondary outcomes included direction of catheter tip against vein wall, distance away from vein wall, vasospasm, and laminar/turbulent flow.Results: Data from December 2023 included 28 catheters (10 PIVC 1, 18 PIVC 2). The average patient age was 53.7 years; 53.6% were female. Vein diameter/depth were similar: 0.35 cm/0.41 cm for PIVC 1 and 0.37 cm/0.47 cm for PIVC 2. The catheter tip pointed posteriorly towards the vein wall in 60% of PIVC 1 vs 11.1% in PIVC 2 (P=0.018). The angle of infusate flow away from the vein wall was 0.20° (SD 0.63) for PIVC 1 and 7.61° (SD 5.71) for PIVC 2 (P< 0.001). Flow at 0° occurred in 90% of PIVC 1 vs 16.7% in PIVC 2 (P< 0.001).Conclusion: In this exploratory investigation, a peripheral vascular access device with an off-axis tip aperture of demonstrated a sharper infusate flow angle away from the vein wall compared to a traditional central opening device. This redirection may reduce vein wall trauma and complications, though further research is needed to pair clinical outcomes with this technology.Keywords: peripheral intravenous access, hemodilution, flow pattern, infusates, modified catheter tip, catheter length

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Infusate Flow Patterns for Minimizing Vein Wall Trauma: An Exploratory Study with a Modified off-Axis Catheter Tip Opening

SHILAP Revista de lepidopterología
Central Venous Catheters and Hemodialysis
article

Optimizing Infusate Flow Patterns for Minimizing Vein Wall Trauma: An Exploratory Study with a Modified off-Axis Catheter Tip Opening

article en

Abstract

Amit Bahl,1 S Matthew Gibson,2 Alexis Walton3 1Department of Emergency Medicine, Oakland University William Beaumont School of Medicine, Rochester, MI, USA; 2Vascular Access Consulting, Henderson, KY, USA; 3Department of Emergency Medicine, Corewell Health William Beaumont University Hospital, Royal Oak, MI, USACorrespondence: Amit Bahl, Oakland University William Beaumont School of Medicine, 586 Pioneer Drive, Rochester, MI, 48309, USA, Email [email protected]: Modifying the PIVC tip to direct infusates toward areas of highest hemodilution may reduce vein wall damage. This study compared flow patterns between a traditional PIVC with a central opening and one with an off-axis aperture.Methods: This was an exploratory observational analysis conducted at a tertiary care emergency department (ED) comparing flow patterns of two intravenous catheters: PIVC 1 (2.95 cm 20 gauge [Autoguard, Becton Dickinson]) and PIVC 2 (3.68 cm 20 gauge [Osprey, SkyDance Vascular]). Adult ED patients with PIVCs placed via traditional palpation/visualization method and with ultrasound capturing the flushing were eligible participants. Ultrasounds were reviewed to determine vein, catheter, and flow characteristics. The primary outcome was angle of the infusate leaving the catheter. Secondary outcomes included direction of catheter tip against vein wall, distance away from vein wall, vasospasm, and laminar/turbulent flow.Results: Data from December 2023 included 28 catheters (10 PIVC 1, 18 PIVC 2). The average patient age was 53.7 years; 53.6% were female. Vein diameter/depth were similar: 0.35 cm/0.41 cm for PIVC 1 and 0.37 cm/0.47 cm for PIVC 2. The catheter tip pointed posteriorly towards the vein wall in 60% of PIVC 1 vs 11.1% in PIVC 2 (P=0.018). The angle of infusate flow away from the vein wall was 0.20° (SD 0.63) for PIVC 1 and 7.61° (SD 5.71) for PIVC 2 (P< 0.001). Flow at 0° occurred in 90% of PIVC 1 vs 16.7% in PIVC 2 (P< 0.001).Conclusion: In this exploratory investigation, a peripheral vascular access device with an off-axis tip aperture of demonstrated a sharper infusate flow angle away from the vein wall compared to a traditional central opening device. This redirection may reduce vein wall trauma and complications, though further research is needed to pair clinical outcomes with this technology.Keywords: peripheral intravenous access, hemodilution, flow pattern, infusates, modified catheter tip, catheter length

SHILAP Revista de lepidopterología
Good health and well-being
Openalex Percentile: Top 39%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.