MRI Pulse Sequence Development and Accelerated Imaging

Magnetic resonance imaging (MRI) of the lungs using hyperpolarized gases (e.g., 3He, 129Xe) is a powerful, non-invasive diagnostic tool for the characterization and treatment of various lung conditions, giving clinicians the ability to directly image the lung microstructure and observe gas exchange. However, non-healthy patients most likely to require pulmonary MRI scans will also present with reduced lung function, limiting their ability to hold their breaths for long periods of time (typical breath-holds are 16 sec). It is known that the optimal field strength range for pulmonary MRI using hyperpolarized gases lie much lower than clinical field strengths, between 0.1 T and 0.6 T. The low field regime offers longer T2* relaxation and higher signal-to-noise ratio for this application: these advantages facilitate certain types of imaging (e.g., longer diffusion times) and diagnostic capabilities, and the low field scanners could potentially help address a clinical need for lung imaging tools. Thus, this thesis aims to improve imaging quality of conventional proton-based MRI at low field, and accelerate pulmonary MRI. Clinical adoption of low field MRI is hindered by the inherent low signal and resolution of 1H-based imaging; dedicated advanced imaging methods and hardware may be able to remedy these issues. The first part of this work consists of the development of the X-Centric pulse sequence for low field MRI. This sequence has an ultra-short echo time with short acquisition windows, maximizing signal for short signal-lifetime samples. Most clinical applications of undersampled MRI are limited to 2 or 3-fold acceleration. Recently, the SIDER (SIgnal DEcay into the Reconstruction) reconstruction method has shown considerable performance for up to 10-fold acceleration, but was limited to diffusion imaging. A signal model of RF depolarization was introduced in this thesis to permit static ventilation imaging with this method, and a novel image averaging scheme was developed to significantly accelerate low field MRI whilst improving image quality: 14-fold acceleration in human lungs was made possible in this work (not yet clinically viable). This thesis presents novel imaging techniques and tools for low field and pulmonary MRI, resulting in significant acceleration and improvements in signal and image quality.

Publication Details

Journal
Scholarship@Western (Western University)
Published
2025-04-22
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MRI Pulse Sequence Development and Accelerated Imaging

Scholarship@Western (Western University)
Atomic and Subatomic Physics Research
article

MRI Pulse Sequence Development and Accelerated Imaging

article en

Abstract

Magnetic resonance imaging (MRI) of the lungs using hyperpolarized gases (e.g., 3He, 129Xe) is a powerful, non-invasive diagnostic tool for the characterization and treatment of various lung conditions, giving clinicians the ability to directly image the lung microstructure and observe gas exchange. However, non-healthy patients most likely to require pulmonary MRI scans will also present with reduced lung function, limiting their ability to hold their breaths for long periods of time (typical breath-holds are 16 sec). It is known that the optimal field strength range for pulmonary MRI using hyperpolarized gases lie much lower than clinical field strengths, between 0.1 T and 0.6 T. The low field regime offers longer T2* relaxation and higher signal-to-noise ratio for this application: these advantages facilitate certain types of imaging (e.g., longer diffusion times) and diagnostic capabilities, and the low field scanners could potentially help address a clinical need for lung imaging tools. Thus, this thesis aims to improve imaging quality of conventional proton-based MRI at low field, and accelerate pulmonary MRI. Clinical adoption of low field MRI is hindered by the inherent low signal and resolution of 1H-based imaging; dedicated advanced imaging methods and hardware may be able to remedy these issues. The first part of this work consists of the development of the X-Centric pulse sequence for low field MRI. This sequence has an ultra-short echo time with short acquisition windows, maximizing signal for short signal-lifetime samples. Most clinical applications of undersampled MRI are limited to 2 or 3-fold acceleration. Recently, the SIDER (SIgnal DEcay into the Reconstruction) reconstruction method has shown considerable performance for up to 10-fold acceleration, but was limited to diffusion imaging. A signal model of RF depolarization was introduced in this thesis to permit static ventilation imaging with this method, and a novel image averaging scheme was developed to significantly accelerate low field MRI whilst improving image quality: 14-fold acceleration in human lungs was made possible in this work (not yet clinically viable). This thesis presents novel imaging techniques and tools for low field and pulmonary MRI, resulting in significant acceleration and improvements in signal and image quality.

Scholarship@Western (Western University)
Openalex Percentile: Top 52%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

MRI Pulse Sequence Development and Accelerated Imaging · Scholarship@Western (Western University) (2025) | TGRS Research Map | TGRS