Instability and Stabilization Filter of df/dt-Type Virtual Inertia Control Comparing to Synchronous Machines

With the increase of inverter-based resources, the reduction in grid inertia has become an issue. To overcome this problem, various virtual inertia controls have been proposed. df/dt control is a candidate for practical application since it can be integrated into conventional current controlled inverters. However, df/dt control can make the system unstable under certain conditions. A common solution is to use a low-pass filter (LPF), but there is no clear answer to why df/dt control becomes unstable and the LPF can improve stability. As a result, there are no general design criteria of the LPF for various plants. This paper focuses on the stability of a current-controlled inverter with df/dt -type virtual inertia control. The authors analyze the dynamic characteristics of a synchronous generator and demonstrate the existence of a second-order delay between the frequency of the point of common coupling (PCC) voltage and the speed of the rotor. The result demonstrates an equivalence between this delay and LPF for stabilization in df/dt control. Then, this second-order delay is implemented in df/dt control as an LPF. The influence of this LPF for stability is analyzed by EMT simulations and Bode plot of the entire system. These results illustrate that the LPF is indispensable for df/dt control, and parameters corresponding to synchronous generators can be used as a design criterion of the LPF.

Publication Details

Journal
Tokyo Tech Research Repository (Tokyo Institute of Technology)
Published
2025-05-01
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Instability and Stabilization Filter of df/dt-Type Virtual Inertia Control Comparing to Synchronous Machines

Tokyo Tech Research Repository (Tokyo Institute of Technology)
Microgrid Control and Optimization
article

Instability and Stabilization Filter of df/dt-Type Virtual Inertia Control Comparing to Synchronous Machines

article en

Abstract

With the increase of inverter-based resources, the reduction in grid inertia has become an issue. To overcome this problem, various virtual inertia controls have been proposed. df/dt control is a candidate for practical application since it can be integrated into conventional current controlled inverters. However, df/dt control can make the system unstable under certain conditions. A common solution is to use a low-pass filter (LPF), but there is no clear answer to why df/dt control becomes unstable and the LPF can improve stability. As a result, there are no general design criteria of the LPF for various plants. This paper focuses on the stability of a current-controlled inverter with df/dt -type virtual inertia control. The authors analyze the dynamic characteristics of a synchronous generator and demonstrate the existence of a second-order delay between the frequency of the point of common coupling (PCC) voltage and the speed of the rotor. The result demonstrates an equivalence between this delay and LPF for stabilization in df/dt control. Then, this second-order delay is implemented in df/dt control as an LPF. The influence of this LPF for stability is analyzed by EMT simulations and Bode plot of the entire system. These results illustrate that the LPF is indispensable for df/dt control, and parameters corresponding to synchronous generators can be used as a design criterion of the LPF.

Tokyo Tech Research Repository (Tokyo Institute of Technology)
Openalex Percentile: Top 45%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Instability and Stabilization Filter of df/dt-Type Virtual Inertia Control Comparing to Synchronous Machines · Tokyo Tech Research Repository (Tokyo Institute of Technology) (2025) | TGRS Research Map | TGRS