GPR-1194 Computer Vision-Enhanced Spectroscopy for Glucose Prediction: An In Vitro Validation Study

This study introduces a novel computer vision-based spectral approach for non-invasive glucose detection using synthetic blood samples. We developed an experimental setup with glucose concentrations from 70 to 120 mg/dL, using two dye methods. Light sources tested included an 850 nm LED, 850 nm laser, 808 nm laser, and 650 nm laser, with image capture via a 1080p IR camera. Data augmentation, including Gaussian noise, contrast and brightness adjustments, rotations, and zooming, produced seven variants per image. Three machine learning models—CNN, AdaBoost, and ResNet—were evaluated, with the 850 nm light source yielding the best results: 87.5% of predictions fell within Zone A of the Clarke Error Grid. Findings support the potential of this approach for non-invasive glucose monitoring.

Publication Details

Journal
DigitalCommons - Kennesaw State University (Kennesaw State University)
Published
2024-11-20
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GPR-1194 Computer Vision-Enhanced Spectroscopy for Glucose Prediction: An In Vitro Validation Study

DigitalCommons - Kennesaw State University (Kennesaw State University)
Spectroscopy Techniques in Biomedical and Chemical Research
article

GPR-1194 Computer Vision-Enhanced Spectroscopy for Glucose Prediction: An In Vitro Validation Study

article en

Abstract

This study introduces a novel computer vision-based spectral approach for non-invasive glucose detection using synthetic blood samples. We developed an experimental setup with glucose concentrations from 70 to 120 mg/dL, using two dye methods. Light sources tested included an 850 nm LED, 850 nm laser, 808 nm laser, and 650 nm laser, with image capture via a 1080p IR camera. Data augmentation, including Gaussian noise, contrast and brightness adjustments, rotations, and zooming, produced seven variants per image. Three machine learning models—CNN, AdaBoost, and ResNet—were evaluated, with the 850 nm light source yielding the best results: 87.5% of predictions fell within Zone A of the Clarke Error Grid. Findings support the potential of this approach for non-invasive glucose monitoring.

DigitalCommons - Kennesaw State University (Kennesaw State University)
Openalex Percentile: Top 45%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.