Boundary analysis of damping methods for virtual synchronous generators

Virtual synchronous generators (VSGs) imitate traditional synchronous generators to provide virtual inertia and damping for inverter-based resources. The emulated damping relates to the power synchronization, therefore, has a major impact on system stability. Although various damping methods exist, phase-locked loop (PLL) integration is particularly concerning, as it is a key component in grid-following (GFL) control but now is being applied to grid-forming (GFM). This paper analyzes the typical VSG control and PLL damping unit by mapping stability boundaries and feasibility range. The boundaries are mapped in two dimensions to determine the relationship between the control parameters and the grid impedance. A comprehensive sensitivity analysis of controller parameters for VSG stability is conducted, drawing parallels with the equivalence of droop-based GFM stability. Finally, the boundary analysis is verified by time-domain simulation results and demonstrates the reliability of damping-switching method.

Publication Details

Journal
ePrints Soton (University of Southampton)
Published
2025-03-07
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Boundary analysis of damping methods for virtual synchronous generators

ePrints Soton (University of Southampton)
Microgrid Control and Optimization
article

Boundary analysis of damping methods for virtual synchronous generators

article en

Abstract

Virtual synchronous generators (VSGs) imitate traditional synchronous generators to provide virtual inertia and damping for inverter-based resources. The emulated damping relates to the power synchronization, therefore, has a major impact on system stability. Although various damping methods exist, phase-locked loop (PLL) integration is particularly concerning, as it is a key component in grid-following (GFL) control but now is being applied to grid-forming (GFM). This paper analyzes the typical VSG control and PLL damping unit by mapping stability boundaries and feasibility range. The boundaries are mapped in two dimensions to determine the relationship between the control parameters and the grid impedance. A comprehensive sensitivity analysis of controller parameters for VSG stability is conducted, drawing parallels with the equivalence of droop-based GFM stability. Finally, the boundary analysis is verified by time-domain simulation results and demonstrates the reliability of damping-switching method.

ePrints Soton (University of Southampton)
Openalex Percentile: Top 45%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.