Встановлення закономірностей формування вогнестійких біокомпозитів для будівництива

The object of this study is the process of forming a heat-insulating layer of foam coke under thermal action on a biocomposite with the presence of an intumescent coating. The task addressed is to establish the effectiveness of the formation of a heat-insulating intumescent layer of foam coke under thermal action on an intumescent coating, which effectively inhibits high temperature. It has been proven that when wood and fabric are treated with fire retardants, chemical bonds arise that characterize symmetric and asymmetric valence vibrations of C–H in the methyl and methylene groups of lignin and cellulose. For wood treated with an intumescent coating, the value of the adhesive strength was set at 0.25 MPa, while the destruction occurred along the polymer shell with a detachment area of about 25 %. For particleboard treated with an intumescent coating, the value of the adhesion strength is about 0.45 MPa, while the failure occurred along the polymer shell with a separation area of about 10 %. Based on the results, it was found that under the action of the burner flame, the temperature of the gaseous combustion products did not exceed 185 °C, and the mass loss was less than 2 %. During the thermal action of the coating, a layer of foam coke more than 20 mm thick was formed. Under the action of the burner flame on the biocomposite based on tarpaulin fabric, intensive swelling of the coating began, which led to the formation of a heat-insulating layer of foam coke more than 9 mm thick, ignition and flame spread did not occur. Thus, the mechanism of fire protection by an intumescent coating is determined by decomposition under the influence of temperature with heat absorption and release of non-combustible gases; by inhibiting oxidation in the gas and condensed phases and by forming a heat-protective coke layer on the surface of the material. The practical significance of the study is that the results related to determining the flame retardant properties of biocomposites could be taken into account when designing fire-resistant structures

Institutions

Publication Details

Journal
The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Published
2025-04-30
Primary Topic
Flame retardant materials and properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Встановлення закономірностей формування вогнестійких біокомпозитів для будівництива

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Flame retardant materials and properties
article

Встановлення закономірностей формування вогнестійких біокомпозитів для будівництива

article en

Abstract

The object of this study is the process of forming a heat-insulating layer of foam coke under thermal action on a biocomposite with the presence of an intumescent coating. The task addressed is to establish the effectiveness of the formation of a heat-insulating intumescent layer of foam coke under thermal action on an intumescent coating, which effectively inhibits high temperature. It has been proven that when wood and fabric are treated with fire retardants, chemical bonds arise that characterize symmetric and asymmetric valence vibrations of C–H in the methyl and methylene groups of lignin and cellulose. For wood treated with an intumescent coating, the value of the adhesive strength was set at 0.25 MPa, while the destruction occurred along the polymer shell with a detachment area of about 25 %. For particleboard treated with an intumescent coating, the value of the adhesion strength is about 0.45 MPa, while the failure occurred along the polymer shell with a separation area of about 10 %. Based on the results, it was found that under the action of the burner flame, the temperature of the gaseous combustion products did not exceed 185 °C, and the mass loss was less than 2 %. During the thermal action of the coating, a layer of foam coke more than 20 mm thick was formed. Under the action of the burner flame on the biocomposite based on tarpaulin fabric, intensive swelling of the coating began, which led to the formation of a heat-insulating layer of foam coke more than 9 mm thick, ignition and flame spread did not occur. Thus, the mechanism of fire protection by an intumescent coating is determined by decomposition under the influence of temperature with heat absorption and release of non-combustible gases; by inhibiting oxidation in the gas and condensed phases and by forming a heat-protective coke layer on the surface of the material. The practical significance of the study is that the results related to determining the flame retardant properties of biocomposites could be taken into account when designing fire-resistant structures

The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy
Kyiv National University of Construction and Architecture (UA), National University of Civil Protection of Ukraine (UA)
Sustainable cities and communities
Openalex Percentile: Top 58%
Flame retardant materials and properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.