Uncertainty-Aware Shared Control for Vision-Based Micromanipulation

This paper presents an uncertainty-aware shared control and calibration method for micromanipulation using a digital microscope and a tool-mounted, multi-joint robotic arm, integrating real-time human intervention with a visual-motor policy. Our calibration algorithm leverages co-manipulation control to calibrate the hand-eye transformation without re-quiring knowledge of the kinematics of the microtool mounted on the robot while remaining robust to camera intrinsics errors.<br/>Experimental results show that the proposed calibration method achieves a 39.6% improvement in accuracy over established methods. Additionally, our control structure and calibration method reduces the time required to reach single-point targets<br/>from 5.74 s (best conventional method) to 1.91 s, and decreases trajectory tracking errors from 392 µm to 40 µm. These findings establish our method as a robust solution for improving reliability in high-precision biomedical micromanipulation.

Institutions

Publication Details

Journal
Research Portal (King's College London)
Published
2025-06-15
Primary Topic
Linguistics and Language Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty-Aware Shared Control for Vision-Based Micromanipulation

Research Portal (King's College London)
Linguistics and Language Analysis
article

Uncertainty-Aware Shared Control for Vision-Based Micromanipulation

article en

Abstract

This paper presents an uncertainty-aware shared control and calibration method for micromanipulation using a digital microscope and a tool-mounted, multi-joint robotic arm, integrating real-time human intervention with a visual-motor policy. Our calibration algorithm leverages co-manipulation control to calibrate the hand-eye transformation without re-quiring knowledge of the kinematics of the microtool mounted on the robot while remaining robust to camera intrinsics errors.<br/>Experimental results show that the proposed calibration method achieves a 39.6% improvement in accuracy over established methods. Additionally, our control structure and calibration method reduces the time required to reach single-point targets<br/>from 5.74 s (best conventional method) to 1.91 s, and decreases trajectory tracking errors from 392 µm to 40 µm. These findings establish our method as a robust solution for improving reliability in high-precision biomedical micromanipulation.

Research Portal (King's College London)
Society of Interventional Radiology (US)
Openalex Percentile: Top 38%
Linguistics and Language Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.