Gridless adult cervical spine radiography and its' effect on image quality and radiation dose

Introduction: Imaging of the cervical spine in general radiography is most frequently performed using an anti-scatter grid. The purpose of this study was to investigate the effects of a gridless setting on image quality and radiation dose during digital radiography of the anteroposterior (AP) and lateral (LAT) cervical spine. Methods: A phantom study was performed with a variety of tube voltages (63e75 kV) with and without an anti-scatter grid. The tube current time product (mAs) and dose area product (DAP) were recorded and used to calculate effective dose (ED) and individual organ dose using PCXMC 2.0 software, as well as entrance surface dose (ESD) and objective image quality: signal-to-noise ratio (SNR) and contrast-tonoise ratio (CNR). Subjective visual image quality grading characteristics (VGC) was performed by five qualified radiographers. Results: In a gridless setting, the AP and LAT positions showed significantly lower DAP (1.6 mGym2 ; 61.3 % and 1.6 mGym2 ; 51.2%), ESD (27.6 mGy; 57.3% and 77.2 mGy; 47.2%) and ED (4.2 mSv; 61.3% and 2.3 mSv; 48.9%). In a gridless setting in the AP position, there is a slight significant deterioration in image quality. In the lateral projection, on the other hand, the image quality without the use of grid was only significantly reduced in three of six criteria and there was no difference in the objective image quality between the two settings examined. Conclusion: The results of this study show that gridless setting significantly decreases radiation dose and image quality, but the quality in the lateral projection is still acceptable for diagnostic purpose. Implications for practice: The protocol without the use of the anti-scatter grid in cervical spine radiography leads to a reduction in the radiation dose in both projections, but the image quality in the AP is significantly reduced for all criteria examined, with a slight deterioration in image quality in the lateral projection.

Publication Details

Journal
Repository of the University of Ljubljana (University of Ljubljana)
Published
2024-12-22
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gridless adult cervical spine radiography and its' effect on image quality and radiation dose

Repository of the University of Ljubljana (University of Ljubljana)
Digital Radiography and Breast Imaging
article

Gridless adult cervical spine radiography and its' effect on image quality and radiation dose

article en

Abstract

Introduction: Imaging of the cervical spine in general radiography is most frequently performed using an anti-scatter grid. The purpose of this study was to investigate the effects of a gridless setting on image quality and radiation dose during digital radiography of the anteroposterior (AP) and lateral (LAT) cervical spine. Methods: A phantom study was performed with a variety of tube voltages (63e75 kV) with and without an anti-scatter grid. The tube current time product (mAs) and dose area product (DAP) were recorded and used to calculate effective dose (ED) and individual organ dose using PCXMC 2.0 software, as well as entrance surface dose (ESD) and objective image quality: signal-to-noise ratio (SNR) and contrast-tonoise ratio (CNR). Subjective visual image quality grading characteristics (VGC) was performed by five qualified radiographers. Results: In a gridless setting, the AP and LAT positions showed significantly lower DAP (1.6 mGym2 ; 61.3 % and 1.6 mGym2 ; 51.2%), ESD (27.6 mGy; 57.3% and 77.2 mGy; 47.2%) and ED (4.2 mSv; 61.3% and 2.3 mSv; 48.9%). In a gridless setting in the AP position, there is a slight significant deterioration in image quality. In the lateral projection, on the other hand, the image quality without the use of grid was only significantly reduced in three of six criteria and there was no difference in the objective image quality between the two settings examined. Conclusion: The results of this study show that gridless setting significantly decreases radiation dose and image quality, but the quality in the lateral projection is still acceptable for diagnostic purpose. Implications for practice: The protocol without the use of the anti-scatter grid in cervical spine radiography leads to a reduction in the radiation dose in both projections, but the image quality in the AP is significantly reduced for all criteria examined, with a slight deterioration in image quality in the lateral projection.

Repository of the University of Ljubljana (University of Ljubljana)
Openalex Percentile: Top 43%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Gridless adult cervical spine radiography and its' effect on image quality and radiation dose · Repository of the University of Ljubljana (University of Ljubljana) (2024) | TGRS Research Map | TGRS