Factors Influencing the Length of Emergency Intensive Care Unit Stay in Adult Tetanus Patients

Ji Xu,1 Ying Wang,2 Guoqing Huang,1 Liping Zhou,1 Xiaoye Mo,1 Ning Yang,1 Ping Wu,1 Shanshan Hu,1 Changshou She1 1Department of Emergency Medicine, Xiangya Hospital, Central South University, Changsha, Hunan, People’s Republic of China; 2Xiangya Medical Academic Promotion Center, Xiangya Hospital, Central South University, Changsha, Hunan, People’s Republic of ChinaCorrespondence: Changshou She, Department of Emergency Medicine, Xiangya Hospital, Central South University, Xiangya Road 87, Changsha, Hunan, 410008, People’s Republic of China, Tel +86 15116331879, Email [email protected]: Tetanus remains a public health problem in developing countries. Patients with severe tetanus require long-term access to emergency medical resources. Here, we identified the risk factors for a prolonged length of stay (LOS) in the emergency intensive care unit (EICU) in adult tetanus patients.Methods: We conducted a retrospective study using data from adult tetanus patients admitted to the EICU in our hospitals. K‒M analysis was used for LOS analysis in the EICU, and the Log rank test was used for comparisons between groups. Cox proportional hazards regression model analyses were used to assess significant factors associated with LOS in the EICU.Results: A total of 81 tetanus patients were included in the study. The patients had an average age of 59.39 ± 10.90 years (SD). The mean LOS was 18.1 days (median, 16.0 days; range, 0.6 days to 50.0 days). From 15 related factors, we identified two independent factors for prolonging the LOS of tetanus patients in the EICU: tracheotomy and mechanical ventilation. The risk of EICU retention in patients with mechanical ventilation was 55.3% greater than that in patients without mechanical ventilation (HR=0.447, 95% CI: 0.227– 0.880, P=0.020); the risk of EICU retention was 86.2% greater in patients with tracheotomy than in those without tracheotomy (HR=0.138, 95% CI: 0.058– 0.328, P< 0.001).Conclusion: Tracheotomy and mechanical ventilation support were associated with increased LOS in the EICU in adult tetanus patients, independent of the tetanus antitoxin dose. Clinicians must focus on spasm control and optimize airway management in tetanus patients in the EICU.Keywords: tetanus, intensive care unit, length of stay, influencing factor, tracheotomy, mechanical ventilation

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
Primary Topic
Military, Security, and Education Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors Influencing the Length of Emergency Intensive Care Unit Stay in Adult Tetanus Patients

SHILAP Revista de lepidopterología
Military, Security, and Education Studies
article

Factors Influencing the Length of Emergency Intensive Care Unit Stay in Adult Tetanus Patients

article en

Abstract

Ji Xu,1 Ying Wang,2 Guoqing Huang,1 Liping Zhou,1 Xiaoye Mo,1 Ning Yang,1 Ping Wu,1 Shanshan Hu,1 Changshou She1 1Department of Emergency Medicine, Xiangya Hospital, Central South University, Changsha, Hunan, People’s Republic of China; 2Xiangya Medical Academic Promotion Center, Xiangya Hospital, Central South University, Changsha, Hunan, People’s Republic of ChinaCorrespondence: Changshou She, Department of Emergency Medicine, Xiangya Hospital, Central South University, Xiangya Road 87, Changsha, Hunan, 410008, People’s Republic of China, Tel +86 15116331879, Email [email protected]: Tetanus remains a public health problem in developing countries. Patients with severe tetanus require long-term access to emergency medical resources. Here, we identified the risk factors for a prolonged length of stay (LOS) in the emergency intensive care unit (EICU) in adult tetanus patients.Methods: We conducted a retrospective study using data from adult tetanus patients admitted to the EICU in our hospitals. K‒M analysis was used for LOS analysis in the EICU, and the Log rank test was used for comparisons between groups. Cox proportional hazards regression model analyses were used to assess significant factors associated with LOS in the EICU.Results: A total of 81 tetanus patients were included in the study. The patients had an average age of 59.39 ± 10.90 years (SD). The mean LOS was 18.1 days (median, 16.0 days; range, 0.6 days to 50.0 days). From 15 related factors, we identified two independent factors for prolonging the LOS of tetanus patients in the EICU: tracheotomy and mechanical ventilation. The risk of EICU retention in patients with mechanical ventilation was 55.3% greater than that in patients without mechanical ventilation (HR=0.447, 95% CI: 0.227– 0.880, P=0.020); the risk of EICU retention was 86.2% greater in patients with tracheotomy than in those without tracheotomy (HR=0.138, 95% CI: 0.058– 0.328, P< 0.001).Conclusion: Tracheotomy and mechanical ventilation support were associated with increased LOS in the EICU in adult tetanus patients, independent of the tetanus antitoxin dose. Clinicians must focus on spasm control and optimize airway management in tetanus patients in the EICU.Keywords: tetanus, intensive care unit, length of stay, influencing factor, tracheotomy, mechanical ventilation

SHILAP Revista de lepidopterología
Partnerships for the goals
Openalex Percentile: Top 40%
Military, Security, and Education Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.