The Effect of 0.05D Interval Precise Refraction on Small-Incision Lenticule Extraction Surgery: A Retrospective Study with Short-Term Follow-Up

Jiaxi Li,1,* Jing Zhen,2,* Ke Xie,2 Kaihua Yao,2 Ziyuan Liu,1 Xuemin Li1 1Department of Ophthalmology, Peking University Third Hospital, Beijing, People’s Republic of China; 2Beijing Meiermu Hospital, Beijing, People’s Republic of China*These authors contributed equally to this workCorrespondence: Ziyuan Liu; Xuemin Li, Department of Ophthalmology, Peking University Third Hospital, Number Forty-Nine North Garden Road Haidian District, Beijing, 100191, People’s Republic of China, Email [email protected]; [email protected]: To compare the postoperative visual quality of patients undergoing small-incision lenticule extraction (SMILE) with spherical trial lens intervals of 0.05D and 0.25D in preoperative manifest refraction.Methods: The study included 196 eyes of 101 patients with 0.05D intervals to perform manifest refraction and 194 eyes of 98 patients with 0.25D intervals. Intraoperative lenticule thickness was compared in patients with different myopic grades. Postoperative examinations, including uncorrected distance visual acuity (UDVA) and manifest refraction results, were compared at 1-day, 1-week and 1-month follow-up.Results: At the one-month follow-up, there was no significant difference in UDVA and spherical equivalent (SE) between the two groups (P=0.602 and 0.898, respectively). But the proportion of patients with a UDVA of more than 0.0 one month postoperatively was higher in the 0.05D intervals group (P=0.067). In patients with moderate myopia, the corneas with 0.05D interval manifest refraction had thinner maximum lenticule thickness compared with those in the control group (P=0.019).Conclusion: Compared with the 0.25D interval group, patients performed manifest refraction with 0.05D spherical lens interval obtained equally good postoperative visual quality. The moderate myopia patients in the 0.05D interval group had thinner cornea cut during SMILE.Keywords: small-incision lenticule extraction, manifest refraction, refractive surgery

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
Primary Topic
Advanced Malware Detection Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of 0.05D Interval Precise Refraction on Small-Incision Lenticule Extraction Surgery: A Retrospective Study with Short-Term Follow-Up

SHILAP Revista de lepidopterología
Advanced Malware Detection Techniques
article

The Effect of 0.05D Interval Precise Refraction on Small-Incision Lenticule Extraction Surgery: A Retrospective Study with Short-Term Follow-Up

article en

Abstract

Jiaxi Li,1,* Jing Zhen,2,* Ke Xie,2 Kaihua Yao,2 Ziyuan Liu,1 Xuemin Li1 1Department of Ophthalmology, Peking University Third Hospital, Beijing, People’s Republic of China; 2Beijing Meiermu Hospital, Beijing, People’s Republic of China*These authors contributed equally to this workCorrespondence: Ziyuan Liu; Xuemin Li, Department of Ophthalmology, Peking University Third Hospital, Number Forty-Nine North Garden Road Haidian District, Beijing, 100191, People’s Republic of China, Email [email protected]; [email protected]: To compare the postoperative visual quality of patients undergoing small-incision lenticule extraction (SMILE) with spherical trial lens intervals of 0.05D and 0.25D in preoperative manifest refraction.Methods: The study included 196 eyes of 101 patients with 0.05D intervals to perform manifest refraction and 194 eyes of 98 patients with 0.25D intervals. Intraoperative lenticule thickness was compared in patients with different myopic grades. Postoperative examinations, including uncorrected distance visual acuity (UDVA) and manifest refraction results, were compared at 1-day, 1-week and 1-month follow-up.Results: At the one-month follow-up, there was no significant difference in UDVA and spherical equivalent (SE) between the two groups (P=0.602 and 0.898, respectively). But the proportion of patients with a UDVA of more than 0.0 one month postoperatively was higher in the 0.05D intervals group (P=0.067). In patients with moderate myopia, the corneas with 0.05D interval manifest refraction had thinner maximum lenticule thickness compared with those in the control group (P=0.019).Conclusion: Compared with the 0.25D interval group, patients performed manifest refraction with 0.05D spherical lens interval obtained equally good postoperative visual quality. The moderate myopia patients in the 0.05D interval group had thinner cornea cut during SMILE.Keywords: small-incision lenticule extraction, manifest refraction, refractive surgery

SHILAP Revista de lepidopterología
Openalex Percentile: Top 56%
Advanced Malware Detection Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Effect of 0.05D Interval Precise Refraction on Small-Incision Lenticule Extraction Surgery: A Retrospective Study with Short-Term Follow-Up · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS