Development and optimization of plastic scintillating fibers for small field dosimetry in external beam radiotherapy

The presented work is about the development of Plastic Scintillating Detectors (PSDs) for small photon field dosimetry in external beam radiotherapy. PSDs were chosen for their water-equivalence, energy-independent response and high spatial resolution, in addition to their real-time response. Several prototypes have been built, using plastic scintillating fibers optically coupled to either a plastic or silica clear optical fiber that transmitted the scintillation light to the read-out system, a Charge-Coupled Device (CCD) camera. The scintillators sensitive volumes were between 0.196 and 0.785 mm3 , to minimize the effects of volume averaging also in small field sizes. These prototypes have been tested at a clinical TrueBeam LINAC by irradiating them with photons. Linearity was tested and field output factors were measured for various square fields, down to 1 × 1 cm2 , both in solid water and in water. The Čerenkov light contribution, originating mainly in the clear fiber, was corrected with a chromatic removal technique by using two optical bandpass filters in distinct wavelength regions. The results show that, after the Čerenkov correction, the prototypes signal is linear with dose and the measured output factors are in good agreement (within 1÷2 %) with those measured with different dosimeters under the same experimental conditions (reference conditions). Such results outline the already assessed PSDs effectiveness in small photon fields dosimetry and justify the effort in developing new prototypes optimized in terms of: detector size, further reducing volume averaging effects; read-out system, photodiodes could replace the CCD camera and allow real-time measurements; overall assembling and optical coupling techniques, to minimize light loss and therefore maximize signal.

Publication Details

Journal
Electronic Theses and Dissertations Repository (University of Pisa)
Published
2025-05-16
Primary Topic
Historical Economic and Social Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and optimization of plastic scintillating fibers for small field dosimetry in external beam radiotherapy

Electronic Theses and Dissertations Repository (University of Pisa)
Historical Economic and Social Studies
article

Development and optimization of plastic scintillating fibers for small field dosimetry in external beam radiotherapy

article en

Abstract

The presented work is about the development of Plastic Scintillating Detectors (PSDs) for small photon field dosimetry in external beam radiotherapy. PSDs were chosen for their water-equivalence, energy-independent response and high spatial resolution, in addition to their real-time response. Several prototypes have been built, using plastic scintillating fibers optically coupled to either a plastic or silica clear optical fiber that transmitted the scintillation light to the read-out system, a Charge-Coupled Device (CCD) camera. The scintillators sensitive volumes were between 0.196 and 0.785 mm3 , to minimize the effects of volume averaging also in small field sizes. These prototypes have been tested at a clinical TrueBeam LINAC by irradiating them with photons. Linearity was tested and field output factors were measured for various square fields, down to 1 × 1 cm2 , both in solid water and in water. The Čerenkov light contribution, originating mainly in the clear fiber, was corrected with a chromatic removal technique by using two optical bandpass filters in distinct wavelength regions. The results show that, after the Čerenkov correction, the prototypes signal is linear with dose and the measured output factors are in good agreement (within 1÷2 %) with those measured with different dosimeters under the same experimental conditions (reference conditions). Such results outline the already assessed PSDs effectiveness in small photon fields dosimetry and justify the effort in developing new prototypes optimized in terms of: detector size, further reducing volume averaging effects; read-out system, photodiodes could replace the CCD camera and allow real-time measurements; overall assembling and optical coupling techniques, to minimize light loss and therefore maximize signal.

Electronic Theses and Dissertations Repository (University of Pisa)
Affordable and clean energy
Openalex Percentile: Top 40%
Historical Economic and Social Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.