Determination of Fe3+ in Water Samples by Reduced Schiff Base Ligand

This research presents the development of a method for the quantification of Fe3+ using a reduced Schiff base ligand, which was synthesized via a simple two-step process with a high yield of 84%. The quantification of Fe3+ was analyzed using UV-Visible spectrophotometry. The selective binding of ligand with various cations (Fe3+, Cr3+, Pb2+, Co2+, Cu2+, Zn2+, Cd2+, Hg2+, Mn2+, Ni2+, Fe2+, Mg2+, Ag+, Na+, K+) was investigated. The results revealed that the reduced Schiff base ligand specifically formed a complex with Fe3+, indicated by a new absorption peak in the 350–400 nm range due to ligand-to-metal charge transfer (LMCT). In contrast, other cations induced no significant spectral changes. Quantitative studies of Fe3+ showed that the absorbance at 380 nm increased linearly with Fe3+ concentration, displaying a correlation coefficient (R2) of 0.9994 within the Fe3+ concentration range of 2.00 × 10–6 to 1.00 × 10–3 M. The method exhibited a limit of detection (LOD) of 1.22 × 10–6 M and a limit of quantification (LOQ) of 2.03 × 10–5 M. The reduced Schiff base ligand was successfully applied for Fe3+ quantification in real water samples, corresponding to the results obtained by inductively coupled plasma optical emission spectroscopy (ICP-OES).

Institutions

Publication Details

Journal
SWU eJournals System (Srinakharinwirot University)
Published
2024-12-25
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Fe3+ in Water Samples by Reduced Schiff Base Ligand

SWU eJournals System (Srinakharinwirot University)
Analytical chemistry methods development
article

Determination of Fe3+ in Water Samples by Reduced Schiff Base Ligand

article en

Abstract

This research presents the development of a method for the quantification of Fe3+ using a reduced Schiff base ligand, which was synthesized via a simple two-step process with a high yield of 84%. The quantification of Fe3+ was analyzed using UV-Visible spectrophotometry. The selective binding of ligand with various cations (Fe3+, Cr3+, Pb2+, Co2+, Cu2+, Zn2+, Cd2+, Hg2+, Mn2+, Ni2+, Fe2+, Mg2+, Ag+, Na+, K+) was investigated. The results revealed that the reduced Schiff base ligand specifically formed a complex with Fe3+, indicated by a new absorption peak in the 350–400 nm range due to ligand-to-metal charge transfer (LMCT). In contrast, other cations induced no significant spectral changes. Quantitative studies of Fe3+ showed that the absorbance at 380 nm increased linearly with Fe3+ concentration, displaying a correlation coefficient (R2) of 0.9994 within the Fe3+ concentration range of 2.00 × 10–6 to 1.00 × 10–3 M. The method exhibited a limit of detection (LOD) of 1.22 × 10–6 M and a limit of quantification (LOQ) of 2.03 × 10–5 M. The reduced Schiff base ligand was successfully applied for Fe3+ quantification in real water samples, corresponding to the results obtained by inductively coupled plasma optical emission spectroscopy (ICP-OES).

SWU eJournals System (Srinakharinwirot University)
Srinakharinwirot University (TH)
Thailand International Cooperation Agency
Clean water and sanitation
Openalex Percentile: Top 62%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.