RP-SAM2: Refining Point Prompts for Stable Surgical Instrument Segmentation

Accurate surgical instrument segmentation is essential in cataract surgery for tasks such as skill assessment and workflow optimization. However, limited annotated data makes it difficult to develop fully automatic models. Prompt-based methods like SAM2 offer flexibility yet remain highly sensitive to the point prompt placement, often leading to inconsistent segmentations. We address this issue by introducing RP-SAM2, which incorporates a novel shift block and a compound loss function to stabilize point prompts. Our approach reduces annotator reliance on precise point positioning while maintaining robust segmentation capabilities. Experiments on the Cataract1k dataset demonstrate that RP-SAM2 improves segmentation accuracy, with a 2% mDSC gain, a 21.36% reduction in mHD95, and decreased variance across random single-point prompt results compared to SAM2. Additionally, on the CaDIS dataset, pseudo masks generated by RP-SAM2 for fine-tuning SAM2's mask decoder outperformed those generated by SAM2. These results highlight RP-SAM2 as a practical, stable and reliable solution for semi-automatic instrument segmentation in data-constrained medical settings. The code is available at https://github.com/BioMedIA-MBZUAI/RP-SAM2.

Publication Details

Journal
ArXiv.org
Published
2025-03-25
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RP-SAM2: Refining Point Prompts for Stable Surgical Instrument Segmentation

ArXiv.org
Intraocular Surgery and Lenses
article

RP-SAM2: Refining Point Prompts for Stable Surgical Instrument Segmentation

article en

Abstract

Accurate surgical instrument segmentation is essential in cataract surgery for tasks such as skill assessment and workflow optimization. However, limited annotated data makes it difficult to develop fully automatic models. Prompt-based methods like SAM2 offer flexibility yet remain highly sensitive to the point prompt placement, often leading to inconsistent segmentations. We address this issue by introducing RP-SAM2, which incorporates a novel shift block and a compound loss function to stabilize point prompts. Our approach reduces annotator reliance on precise point positioning while maintaining robust segmentation capabilities. Experiments on the Cataract1k dataset demonstrate that RP-SAM2 improves segmentation accuracy, with a 2% mDSC gain, a 21.36% reduction in mHD95, and decreased variance across random single-point prompt results compared to SAM2. Additionally, on the CaDIS dataset, pseudo masks generated by RP-SAM2 for fine-tuning SAM2's mask decoder outperformed those generated by SAM2. These results highlight RP-SAM2 as a practical, stable and reliable solution for semi-automatic instrument segmentation in data-constrained medical settings. The code is available at https://github.com/BioMedIA-MBZUAI/RP-SAM2.

ArXiv.org
Openalex Percentile: Top 38%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.