Human Activity Recognition from Smartphone Sensor Data for Clinical Trials

We developed a ResNet-based human activity recognition (HAR) model with minimal overhead to detect gait versus non-gait activities and everyday activities (walking, running, stairs, standing, sitting, lying, sit-to-stand transitions). The model was trained and evaluated using smartphone sensor data from adult healthy controls (HC) and people with multiple sclerosis (PwMS) with Expanded Disability Status Scale (EDSS) scores between 0.0-6.5. Datasets included the GaitLab study (ISRCTN15993728), an internal Roche dataset, and publicly available data sources (training only). Data from 34 HC and 68 PwMS (mean [SD] EDSS: 4.7 [1.5]) were included in the evaluation. The HAR model showed 98.4% and 99.6% accuracy in detecting gait versus non-gait activities in the GaitLab and Roche datasets, respectively, similar to a comparative state-of-the-art ResNet model (99.3% and 99.4%). For everyday activities, the proposed model not only demonstrated higher accuracy than the state-of-the-art model (96.2% vs 91.9%; internal Roche dataset) but also maintained high performance across 9 smartphone wear locations (handbag, shopping bag, crossbody bag, backpack, hoodie pocket, coat/jacket pocket, hand, neck, belt), outperforming the state-of-the-art model by 2.8% - 9.0%. In conclusion, the proposed HAR model accurately detects everyday activities and shows high robustness to various smartphone wear locations, demonstrating its practical applicability.

Publication Details

Journal
ArXiv.org
Published
2025-08-07
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Human Activity Recognition from Smartphone Sensor Data for Clinical Trials

ArXiv.org
Balance, Gait, and Falls Prevention
article

Human Activity Recognition from Smartphone Sensor Data for Clinical Trials

article en

Abstract

We developed a ResNet-based human activity recognition (HAR) model with minimal overhead to detect gait versus non-gait activities and everyday activities (walking, running, stairs, standing, sitting, lying, sit-to-stand transitions). The model was trained and evaluated using smartphone sensor data from adult healthy controls (HC) and people with multiple sclerosis (PwMS) with Expanded Disability Status Scale (EDSS) scores between 0.0-6.5. Datasets included the GaitLab study (ISRCTN15993728), an internal Roche dataset, and publicly available data sources (training only). Data from 34 HC and 68 PwMS (mean [SD] EDSS: 4.7 [1.5]) were included in the evaluation. The HAR model showed 98.4% and 99.6% accuracy in detecting gait versus non-gait activities in the GaitLab and Roche datasets, respectively, similar to a comparative state-of-the-art ResNet model (99.3% and 99.4%). For everyday activities, the proposed model not only demonstrated higher accuracy than the state-of-the-art model (96.2% vs 91.9%; internal Roche dataset) but also maintained high performance across 9 smartphone wear locations (handbag, shopping bag, crossbody bag, backpack, hoodie pocket, coat/jacket pocket, hand, neck, belt), outperforming the state-of-the-art model by 2.8% - 9.0%. In conclusion, the proposed HAR model accurately detects everyday activities and shows high robustness to various smartphone wear locations, demonstrating its practical applicability.

ArXiv.org
Openalex Percentile: Top 35%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.