Resonance-free Fabry-P\'erot cavity via unrestricted orbital-angular-momentum ladder-up

Introducing elements into an optical cavity that modify the transverse spatial field structure can also impact the cavity spectral response. In particular, an intra-cavity spatial mode-converter is expected to induce modal runaway: unrestricted ladder-up in the modal order, concomitantly thwarting coherent field interference, thereby altogether suppressing the resonant response - a phenomenon that has yet to be observed in an optical cavity. Here we show that a single intra-cavity holographic phase mask placed in a compact free-standing planar Fabry-P\'erot cavity renders the cavity spectral response resonance-free. By acting as a mode-converter on a basis of Laguerre-Gaussian (LG) modes, an incident broadband fundamental Gaussian mode exits the cavity in the form of a superposition of a large number of collinearly propagating broadband LG modes of fixed parity whose spectra coincide with that of the input. Crucially, the resonance-free spectral response is maintained while changing the cavity length by $\sim350\%$, raising the prospect of stable resonant optical sensors whose performance is impervious to length perturbations.

Publication Details

Journal
ArXiv.org
Published
2025-03-17
Primary Topic
Orbital Angular Momentum in Optics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resonance-free Fabry-P\'erot cavity via unrestricted orbital-angular-momentum ladder-up

ArXiv.org
Orbital Angular Momentum in Optics
article

Resonance-free Fabry-P\'erot cavity via unrestricted orbital-angular-momentum ladder-up

article en

Abstract

Introducing elements into an optical cavity that modify the transverse spatial field structure can also impact the cavity spectral response. In particular, an intra-cavity spatial mode-converter is expected to induce modal runaway: unrestricted ladder-up in the modal order, concomitantly thwarting coherent field interference, thereby altogether suppressing the resonant response - a phenomenon that has yet to be observed in an optical cavity. Here we show that a single intra-cavity holographic phase mask placed in a compact free-standing planar Fabry-P\'erot cavity renders the cavity spectral response resonance-free. By acting as a mode-converter on a basis of Laguerre-Gaussian (LG) modes, an incident broadband fundamental Gaussian mode exits the cavity in the form of a superposition of a large number of collinearly propagating broadband LG modes of fixed parity whose spectra coincide with that of the input. Crucially, the resonance-free spectral response is maintained while changing the cavity length by $\sim350\%$, raising the prospect of stable resonant optical sensors whose performance is impervious to length perturbations.

ArXiv.org
Openalex Percentile: Top 52%
Orbital Angular Momentum in Optics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.