Simulation Studies of the Effect of SiPM Dark Noise on the Performance of a Highly Granular Crystal ECAL

A proposal for the CEPC ECAL is a highly-granular scintillating crystal design that uses SiPMs to measure physics signals from photons. Radiation damage to the silicon will impair the performance of the calorimeter due to dark noise, which will affect the reconstruction capabilities of the calorimeter system. This paper presents a simulation study assessing the effect of radiation damage of SiPM dark noise on the response from calorimeter to electrons due to changing fluence and temperature. It was observed that dark noise significantly degrades the linearity of response, with up to 45% error in reconstructed energy for a 1 GeV shower at a fluence of $1 \times 10^{10}\mathrm{cm}^{-2}$. The stochastic and noise resolution terms was observed to remain stable, increasing only by 0.2% and 1% respectively in the range $1 \times 10^{7}-1 \times 10^{10}\mathrm{cm}^{-2}$ fluence. Under the assumption of no irradiation, the influence of dark noise with temperature in the normal operating range of the calorimeter system was estimated to be negligible.

Publication Details

Journal
ArXiv.org
Published
2025-02-21
Primary Topic
Cell Image Analysis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation Studies of the Effect of SiPM Dark Noise on the Performance of a Highly Granular Crystal ECAL

ArXiv.org
Cell Image Analysis Techniques
article

Simulation Studies of the Effect of SiPM Dark Noise on the Performance of a Highly Granular Crystal ECAL

article en

Abstract

A proposal for the CEPC ECAL is a highly-granular scintillating crystal design that uses SiPMs to measure physics signals from photons. Radiation damage to the silicon will impair the performance of the calorimeter due to dark noise, which will affect the reconstruction capabilities of the calorimeter system. This paper presents a simulation study assessing the effect of radiation damage of SiPM dark noise on the response from calorimeter to electrons due to changing fluence and temperature. It was observed that dark noise significantly degrades the linearity of response, with up to 45% error in reconstructed energy for a 1 GeV shower at a fluence of $1 \times 10^{10}\mathrm{cm}^{-2}$. The stochastic and noise resolution terms was observed to remain stable, increasing only by 0.2% and 1% respectively in the range $1 \times 10^{7}-1 \times 10^{10}\mathrm{cm}^{-2}$ fluence. Under the assumption of no irradiation, the influence of dark noise with temperature in the normal operating range of the calorimeter system was estimated to be negligible.

ArXiv.org
Affordable and clean energy
Openalex Percentile: Top 50%
Cell Image Analysis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.