Toward Automated Regulatory Decision-Making: Trustworthy Medical Device Risk Classification with Multimodal Transformers and Self-Training

Accurate classification of medical device risk levels is essential for regulatory oversight and clinical safety. We present a Transformer-based multimodal framework that integrates textual descriptions and visual information to predict device regulatory classification. The model incorporates a cross-attention mechanism to capture intermodal dependencies and employs a self-training strategy for improved generalization under limited supervision. Experiments on a real-world regulatory dataset demonstrate that our approach achieves up to 90.4% accuracy and 97.9% AUROC, significantly outperforming text-only (77.2%) and image-only (54.8%) baselines. Compared to standard multimodal fusion, the self-training mechanism improved SVM performance by 3.3 percentage points in accuracy (from 87.1% to 90.4%) and 1.4 points in macro-F1, suggesting that pseudo-labeling can effectively enhance generalization under limited supervision. Ablation studies further confirm the complementary benefits of both cross-modal attention and self-training.

Publication Details

Journal
ArXiv.org
Published
2025-05-01
Primary Topic
Adversarial Robustness in Machine Learning
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward Automated Regulatory Decision-Making: Trustworthy Medical Device Risk Classification with Multimodal Transformers and Self-Training

ArXiv.org
Adversarial Robustness in Machine Learning
article

Toward Automated Regulatory Decision-Making: Trustworthy Medical Device Risk Classification with Multimodal Transformers and Self-Training

article en

Abstract

Accurate classification of medical device risk levels is essential for regulatory oversight and clinical safety. We present a Transformer-based multimodal framework that integrates textual descriptions and visual information to predict device regulatory classification. The model incorporates a cross-attention mechanism to capture intermodal dependencies and employs a self-training strategy for improved generalization under limited supervision. Experiments on a real-world regulatory dataset demonstrate that our approach achieves up to 90.4% accuracy and 97.9% AUROC, significantly outperforming text-only (77.2%) and image-only (54.8%) baselines. Compared to standard multimodal fusion, the self-training mechanism improved SVM performance by 3.3 percentage points in accuracy (from 87.1% to 90.4%) and 1.4 points in macro-F1, suggesting that pseudo-labeling can effectively enhance generalization under limited supervision. Ablation studies further confirm the complementary benefits of both cross-modal attention and self-training.

ArXiv.org
Peace, Justice and strong institutions
Openalex Percentile: Top 73%
Adversarial Robustness in Machine Learning
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.